Clemson University
INVESTIGATION OF THE DISCHARGE COEFFICIENT FOR CIRCULAR ORIFICES IN RISER PIPES
Abstract
dc:description.abstractThe purpose of this study is to examine the discharge coefficient as it pertains to flow through a circular orifice cut into a thin-walled vertical riser pipe. Perforated riser pipes are a popular outlet control structure for stormwater detention basins. These basins are used to store and release stormwater runoff from impervious areas of developed sites. Federal, state, and local regulatory agencies provide requirements for the quality of stormwater runoff, as well as the maximum peak discharges from a developed site. Accurately determining the flow rate from a perforated vertical riser pipe is crucial to meeting these requirements and protecting the environment from pollutants found in stormwater runoff. This study therefore investigated several factors that may affect the value of the discharge coefficient. A physical model was built and various size riser pipes were installed in the tank to simulate a detention basin. The discharge through the orifice was determined by measuring the rate of change of the water level in the tank versus time. A water level versus volume drained calibration was used to find the rate of change of volume over time, and hence the discharge coefficient. The study determined that the discharge coefficient increased with decreasing head values. The study also found that the discharge coefficient decreased as the height above the floor was increased, up to a certain point. Another factor found to affect the discharge coefficient was the orifice diameter to riser diameter, or d/D ratio. The discharge coefficient decreases as the d/D ratio is increased. It is postulated that most of the changes to the discharge coefficient are a result of changes to the contraction of the jet exiting the orifice. For orifices away from the influence of the bed, the discharge coefficient vlaues were normalized and compiled to fit a single curve that could be used to determine the discharge coefficient for any orifice size in any riser pipe diameter, for a particular head to orifice diameter ratio. Multiple orifices in the same vertical plane were investigated as a secondary part of the study, but no effect on the discharge was found for the orifice spacings tested.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Civil Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Prohaska, David
- Contributors dc:contributor
-
- Khan, Abdul A
- Kaye , Nigel B
- Testik , Firat Y
Subjects
dc:subject × 5Identifiers
dc:identifier.*- Repository record dc:identifier
- https://open.clemson.edu/all_theses/407