Back to search

Clemson University

Mathematical Properties that Influence Least Significant Change of Body Composition and Bone Mineral Density Measured by Dual Energy X-Ray Absorptiometry

Abstract

dc:description.abstract

Introduction: Dual energy X-ray absorptiometry (DXA) scans are the gold standard method for measuring bone mineral density (BMD) calculations for the assessment and measurement of bone health. More recently, DXA scans have become the common method for body composition assessments among clinicians and researchers alike, particularly for its ability to separate soft tissue into and lean mass. This study was designed to calculate the percent coefficient variation (%CV) to determine the least significant change (LSC), or the variability considered significant when measuring BMD, fat mass, and lean mass with a DXA scan. Methods: Thirty-six female and 6 male, aged 50.07 ± 15.70 years, volunteered in the AP Lumbar Spine scan. Thirty-five female and 7 male, aged 49.81 ± 15.12 volunteered in the whole body scan. Any participant who was pregnant or trying to become pregnant was excluded from the study. Height and weight were measured, and date of birth and race was recorded. Body composition and BMD were measured using a Hologic Discovery QDR Series (Hologic, Inc, Bedford, MA) DXA densitometer. Each participant was scanned three times for each type of scan they volunteered for. Scans were taken consecutively by the same technician, and participants were removed from the table and repositioned immediately thereafter for the next scan. Results were calculated with the International Society of Clinical Densitometry’s (ISCD) calculator. Results: Overall average %CV came within a 1% error as reported by the manufacturer and individual %CV recommendations according to ISCD reports, with the exception of WB Visceral Adipose Tissue (VAT) with a 15.95% error. Of the variables measured, only WB fat mass and lean mass had no outliers or measurements outside the recommended %CV as noted by either the manufacturer or ISCD. Conclusions: Although the average %CV met the manufacturers’ and ISCD recommendations many participants did not fall within the %CV distribution and or contained outliers within the distribution despite meeting the recommendations. In addition, WB VAT mass had the highest percent error. Regardless the cause of such variation in measurements is unclear, and requires further investigation.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Food, Nutrition, and Culinary Science

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Najm, Nadia Marie Ghassan
Contributors dc:contributor
  • Elliot D. Jesch, Ph.D, Committee Chair
  • Michelle M. Bohan Brown, Ph.D
  • Tenly Murphy, MD

Identifiers

dc:identifier.*
Repository record dc:identifier
https://open.clemson.edu/all_theses/2509

Chain of custody

source
Harvested from
Clemson University
Base URL
open.clemson.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Najm, Nadia Marie Ghassan. Mathematical Properties that Influence Least Significant Change of Body Composition and Bone Mineral Density Measured by Dual Energy X-Ray Absorptiometry. Thesis thesis, https://open.clemson.edu/all_theses/2509