Abstract
dc:description.abstractWe describe the design and physical realization of a novel type of large-scale continuum robot. The design, based on a hybrid concentric-tube/tendon actuated structure, is realized at a significantly larger scale than previous concentric tube continuum robots, with an extended length well over one meter. While operation at this scale opens up new types of potential applications, realization at this scale presents interesting challenges. We detail and discuss the associated issues via the prototyping and testing of the physical system with the help of experiments.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Electrical Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Verma, Siddharth R.
- Contributors dc:contributor
-
- Dr. Ian Walker, Committee Chair
- Dr. Apoorva Kapadia
- Dr. Adam Hoover
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Repository record dc:identifier
- https://open.clemson.edu/all_theses/2680