Back to search

Clemson University

Mechanical Characterization of the Mesh-Tissue Composite Using Abdominal Wall Tissue Phantoms and Experimental Simulations

Abstract

dc:description.abstract

Abdominal wall hernias occur when a weakening in the muscle layer allows the protrusion of internal tissues. Hernia repair is a highly common surgical procedure with nearly one-million performed annually during which surgeons may implant surgical mesh to reinforce the weakened muscles and probe by hand to subjectively assess mesh fixation to the abdominal wall. Objective evaluation of mesh implantation relies on the mechanical characterization of the mesh-tissue composite, which is difficult in intra- operative settings. There is a need for tools capable of providing quantitative assessments of the mechanical behavior of mesh in situ. While several metrics exist for characterizing soft tissues, stiffness has been shown to be a parameter relevant to clinical outcome and development of new mesh materials. A novel minimally invasive surgical tool was developed for the mechanical characterization of mesh-tissue composites in terms of their stiffness. Preliminary testing revealed variation in stiffness measurements when a load was applied to the stiffness tool by a user during operation. Through work described in this thesis, the tool was further developed with additional instrumentation to effectively minimize the impact of user-load on stiffness measurement. Characterization of the mesh-tissue composite was accomplished using commercially-available mesh, abdominal wall tissue phantoms, and a custom benchtop simulator that mimics abdominal wall distension and exposes mesh materials to biaxial loading that is comparable to physiological loading conditions.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Bioengineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stanford, Mathew Murphy
Contributors dc:contributor
  • Melinda Harman, PhD, Committee Chair
  • Jeremy Mercuri, PhD
  • B. Todd Heniford, MD

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://open.clemson.edu/all_theses/2905

Chain of custody

source
Harvested from
Clemson University
Base URL
open.clemson.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Stanford, Mathew Murphy. Mechanical Characterization of the Mesh-Tissue Composite Using Abdominal Wall Tissue Phantoms and Experimental Simulations. Thesis thesis, https://open.clemson.edu/all_theses/2905