Back to search

Clemson University

Existing Building Codes and Historic Masonry Towers

Abstract

dc:description.abstract

The existing building codes offer exemptions for historic structures that lessen the prescriptive requirements and offer alternative means to achieve life safety goals. Three examples selected for this study are unreinforced masonry towers subject to high wind loads and seismic forces to explore the methods of Prescriptive, Work Area, and Performance Compliance with an eye to the role of the building code official and where the decisions may impact life safety in the course of repairing, altering, or changing the occupancy of the towers. The thesis explores the complexity of the code while forming a roadmap of the process. As the American Institute of Architects and Association for Preservation Technology send out a call to professionals to better understand and increase their involvement in the code development cycles at ICC, this thesis might offer a point of discussion about the nature of hard-to-follow codes and the impact it has on life safety.

Degree

thesis:*
Name thesis:degree_name
Master of Historic Preservation (MHP)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Planning, Development, and Preservation

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bennett, John Sheridan
Contributors dc:contributor
  • Amalia Liefeste
  • Ashley K Jennings
  • Melvyn Green

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://open.clemson.edu/all_theses/3303

Chain of custody

source
Harvested from
Clemson University
Base URL
open.clemson.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation