Back to search

Universidade de Coimbro

Qualidade da água em sistemas de arrefecimento na indústria, abordagem legislativa: Estudo de caso.

Abstract

dc:description.abstract

The heat produced in many processes in the chemical industry must be dissipated to maintain process conditions and achieve the desired performance. Cooling towers and evaporative condensers are systems that commonly operate in an open circuit with water recirculation, used for cooling thermal fluids, which allows their reuse. Ensuring the quality of the water circulating in these systems is a concern at various levels, because of the repercussions on the operation and maintenance of the equipment, and also because the impact that this may have on the population's health, like the occurrence of legionnaires' disease. Thus, the objective of the work was to examine cooling systems in industry from the point of view of the current legislation of prevention and control of the proliferation and dissemination of Legionella.In the first phase, the study focused on a survey of the characteristics and operation of cooling towers and evaporative condensers and on the analysis of the factors that influence their good performance. The contribution of the properties of the water circulating in this equipment to minimize the occurrence of corrosion, incrustations and microbiological contamination was analyzed and measures for the quality control of the water are presented. The publication of legislation for the prevention and control of the spread of the Legionella bacteria led to the legal obligation of companies with cooling equipment to draw up a Legionella Prevention and Control Plan. This work presents a proposal for this prevention plan contemplating the application of Law (Lei) n.º 52/2018 and Ordinance (Portaria) n.º 25/2021. The plan proposed involves preventive measures and monitoring the operation of this equipment to prevent the appearance of Legionella. The measures referred to in the previous document include a program to maintain and check the equipment for signs of corrosion and a preventive or corrective monitoring and treatment of the water in circulation. The evaluation of quality of water may involve the determination of Langelier and Ryznar Indexes which indicate the encrusting or corrosive tendency of the water. On the other hand, measuring the residual free chlorine content makes an evaluation of the efficiency of the microbiological treatment implemented with relation to the dosage and type of biocide used possible.This dissertation also involved a practical component of evaluation of the quality of water in three different industrial plants in a total of five cooling systems. The number of visits did not allow the collection of sufficient data for a consolidated characterization of the systems. However, in some of these units the water circulating was evaluated as having a tendency for encrustation, although not severe. This problem could be resolved by regulating the flow rate of the purge current in the unit. In most of the cooling systems analyzed, the residual value of free chlorine registered in the water circulating was below the minimum recommended value. The monitoring of the cooling systems for a longer period would have made it possible to evaluate the results of the corrective measures.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Maleita, Joana Rita Freitas
Advisors dc:contributor.advisor
  • Baptista, Cristina Maria dos Santos Gaudêncio
  • Santiago, Eva Rafael Coelho

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • embargoedAccess
Language dc:language.iso
por

Identifiers

dc:identifier.*
Dc Identifier Tid
202922308

Chain of custody

source
Harvested from
Universidade de Coimbro
Base URL
estudogeral.sib.uc.pt/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Maleita, Joana Rita Freitas. Qualidade da água em sistemas de arrefecimento na indústria, abordagem legislativa: Estudo de caso.. 2021. https://hdl.handle.net/10316/98144