Back to search

Colorado State University. Libraries

Design of an inhalable aerosol size spectrometer

Abstract

dc:description.abstract

Industrial hygienists lack the proper instruments to measure size distributions of inhalable particulate matter (0-100 μm) as defined by ACGIH/ISO/CEN. The Portable Inhalable Particle Spectrometer (PIPS) was designed to size-segregate IPM in calm-air environments – which constitute a majority of workplaces. The PIPS uses an upward air velocity to restrict particle aspiration into the device to diameters above a specified cut-size. A vertical test chamber was also designed to facilitate aerosol dispersion and experimental evaluation of the PIPS. Two PIPS tubes were tested (1.5 cm and 5 cm) at four face velocities (0.6, 1.35, 2.5 and 3.5 cm·s⁻¹) that correspond to cut-sizes of 20, 30, 40 and 50 μm in aerodynamic diameter, respectively. The observed performance of the PIPS deviated from model estimates as face velocity or tube diameter was increased. The fluid regime present inside the chamber, due to the operating PIPS, likely influenced the measured sampling efficiency of the PIPS.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Environmental and Radiological Health Sciences
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Ndonga, Mwangi, author
  • Volckens, John, advisor
  • Reynolds, Stephen, committee member
  • Kreidenweis, Sonia, committee member

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ndonga, Mwangi, author; Volckens, John, advisor; Reynolds, Stephen, committee member; Kreidenweis, Sonia, committee member. Design of an inhalable aerosol size spectrometer. Masters thesis, Colorado State University. Libraries, 2015. http://hdl.handle.net/10217/166860