Back to search

Colorado State University. Libraries

A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth

Abstract

dc:description.abstract

Exposure to airborne particulate matter with diameters less than 2.5 µm (PM2.5) is a leading cause of death and disease globally. In addition to affecting health, PM2.5 affects climate and atmospheric visibility. NASA currently uses satellite imaging technology to measure particulate matter air pollution across the world. Satellite image data are used to derive aerosol optical depth (AOD), which is the extinction of light in the atmospheric column. Although AOD data are often used to estimate surface PM2.5 concentration, there is considerable uncertainty associated with the relationship between satellite-derived AOD and ground-level PM2.5. Instruments known as Sun photometers can measure AOD from the Earth's surface and are often used for validation and calibration of satellite data. Reference-grade Sun photometers generally do not have co-located PM2.5 measurements and are too expensive to deploy in large numbers. The objective of this work was to develop an inexpensive and compact integrated PM2.5 mass and AOD sampler known as the Solar-Powered Aerosol Reference Calibrator (SPARC). PM2.5 is sampled using an ultrasonic pumping system, a size-selective cyclone separator, and a filter. Filter measurements can be used to correct the output from a low-cost direct-reading PM2.5 sensor housed within the SPARC. AOD is measured using optically filtered photodiodes at four discrete wavelengths. A suite of integrated sensors enable time-resolved measurement of key metadata including location, altitude, temperature, barometric pressure, relative humidity, solar incidence angle and spatial orientation. The AOD sensors were calibrated relative to a reference monitor in the Aerosol Robotics Network (AERONET). Field validation studies revealed close agreement for AOD values measured between co-located SPARC and AERONET monitors and for PM2.5 mass measured between co-located SPARC and EPA Federal Reference Method (FRM) monitors. These field validation results for this novel monitor demonstrate that AOD and PM2.5 can be accurately measured for the evaluation of AOD:PM2.5 ratios.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Wendt, Eric, author
  • Volckens, John, advisor
  • Jathar, Shantanu, committee member
  • Yalin, Azer, committee member
  • Pierce, Jeffrey, committee member

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Wendt, Eric, author; Volckens, John, advisor; Jathar, Shantanu, committee member; Yalin, Azer, committee member; Pierce, Jeffrey, committee member. A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth. Masters thesis, Colorado State University. Libraries, 2018. https://hdl.handle.net/10217/189408