Abstract

dc:description.abstract

Current methods to detect low activity radiological sources in areas with elevated or changing background may be insufficient for assessing real-time events. Background radiation fluctuates throughout the day, which thwarts the effectiveness of decision thresholds (y*) extrapolated from long background count times. However, decision thresholds calculated from a string of spectral measurements can be used to optimize the decision threshold (y*) at which count rates statistically exceed background. The goal of this project is to apply a frequentist string data analysis tool to real-time gross count sodium iodide (NaI) spectra under varying background radiation and shielding conditions. A sodium iodide scintillator is utilized with the ProSpect acquisition software to acquire gross count data for analysis of the source detection efficiency under varying background and shielding conditions. A series of measurements is taken using short count times, and assessed using Receiver Operating Characteristics (ROC) curves. The best combination of N measurements, with n events individually exceeding a discriminator threshold, is determined using true positive rates from the generated ROC curves. Ideally, the optimized combination of n exceedances of the discriminator threshold in N measurements discerns weak signals from elevated background, while minimizing false positive events.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Environmental and Radiological Health Sciences
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Fischer, Joseph Christian, author
  • Brandl, Alexander, advisor
  • Johnson, Thomas E., committee member
  • Lindsay, James, committee member

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
Identifier
Fischer_colostate_0053N_15092.pdf

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Fischer, Joseph Christian, author; Brandl, Alexander, advisor; Johnson, Thomas E., committee member; Lindsay, James, committee member. Gross count multi-spectra analysis of weak activity sources amid elevated background and various shielded conditions. Masters thesis, Colorado State University. Libraries, 2018. https://doi.org/10.25675/3.024576