Effect of mixed-mode loading on fatigue and fracture assessment of a steel twin box-girder bridge

Abstract

dc:description.abstract

Steel twin box-girders are considered an attractive option for the construction of bridges due to their basic design, simple form, and ease of creation. Despite their advantages, they are considered fracture critical and as such there is an additional mandate for these bridges to inspected more in depth. This causes their inspection cost to be approximately two to five times greater than that of bridges with non-fracture critical members. The required additional inspection in the U.S. is mainly driven by rare historical events of bridge collapse for bridges that were not steel twin box girders. In addition, the mandated additional inspection does not reflect the inherent level of redundancy in most bridges. Therefore, it is important to quantify the potential for fracture and the level of redundancy in steel two-girder bridges in general, and twin box girders in particular, to minimize their inspection cost. Recognizing the inherently large scatter in fatigue performance, evaluating crack propagation and potential for fracture should, however, be performed in a probabilistic manner using detailed models that represent accurate behavior of the bridge. In this study, a detailed numerical finite element model of steel twin tub-girder bridge is developed and crack growth analysis, potential for fracture of its main tubs, and its overall redundancy is evaluated. The crack growth analysis is performed using multi-mode linear elastic fracture mechanics while accounting for uncertainties in the random variables associated with crack propagation and fracture. The results of the crack growth analysis are utilized to develop fragility functions that specify inspection intervals versus probability of failure where failure is characterized by dynamic crack growth. The analysis conducted to quantify the potential for fracture show distinct possible failure modes that vary from brittle fracture to ductile fracture. The extreme loading case shows that the bridge overall is not at risk of collapse. It is important to note that this conclusion cannot be generalized for all tub girder bridges since the level of redundancy is expected to vary between bridges depending on many factors such as girders geometries, plate thickness, fabrication, among others. However, the presented approach and the corresponding results provide a systematic way by which fracture critical bridges can be evaluated.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Civil and Environmental Engineering
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Irfaee, Mazin M., author
  • Mahmoud, Hussam, advisor
  • Heyliger, Paul, committee member
  • Atadero, Rebecca, committee member
  • Stright, Lisa, committee member

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Irfaee, Mazin M., author; Mahmoud, Hussam, advisor; Heyliger, Paul, committee member; Atadero, Rebecca, committee member; Stright, Lisa, committee member. Effect of mixed-mode loading on fatigue and fracture assessment of a steel twin box-girder bridge. Masters thesis, Colorado State University. Libraries, 2019. https://hdl.handle.net/10217/195407