Back to search

Colorado State University. Libraries

Water-quality data analysis protocol development

Abstract

dc:description.abstract

Several agencies have developed networks to routinely monitor water quantity and quality in an attempt to assess society's influence on the environment, including the impacts of modern agriculture. Data from these networks are often plagued with attributes that inhibit analysis and interpretation. As more and more emphasis and public pressure is placed upon demonstrating environmental results, it is increasingly necessary that a consistent protocol for analyzing data from water quality monitoring networks be developed. Common data record attributes which inhibit data analysis include distribution applicability, variance heterogeneity, seasonality, serial correlation, extreme events, censoring, erroneous observations, small sample size, missing values, different sampling frequencies, multiple observations and measurement uncertainty. Each data record attribute is described in this study. In establishing a protocol to analyze water quality data, the handling of censored data and detection of trends in the presence of serial correlation and missing data are particularly difficult to quantify. This study focuses on these issues of protocol development. Seventeen procedures are evaluated for estimating the mean, median, standard deviation and interquartile range from data sets with singly and multiply censored observations. The results from this evaluation support previous investigations. In addition, the "no censoring” rule was found superior to methods which used censored observations for estimation of the mean, median and standard deviation. This study also compared the use of the Mann-Kendall tau test (and variations) for evaluating monotonic trends in water quality data. The Seasonal Kendall (Mann-Kendall) tau test should be used for data records with no serial correlation and five or less (ten or more) years of record. An ideal test for short data records which have serial correlation was not found in this study. The Seasonal Kendall tau test with serial correlation correction should be used for data sets of at least ten years of record and serial correlation. Furthermore, if monthly data sets have on the order of 40 to 50 percent missing values, monthly data should be collapsed to quarterly data by computing seasonal means or medians.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Agricultural and Chemical Engineering
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
1990

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Harcum, Jonathan Brooks, author
  • Loftis, Jim C., advisor
  • Ward, Robert C., advisor
  • Hirsch, Robert M., committee member
  • Salas, Jose, committee member

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Harcum, Jonathan Brooks, author; Loftis, Jim C., advisor; Ward, Robert C., advisor; Hirsch, Robert M., committee member; Salas, Jose, committee member. Water-quality data analysis protocol development. Doctoral thesis, Colorado State University. Libraries, 1990. https://hdl.handle.net/10217/233935