Back to search

Colorado State University. Libraries

Temperature increase measurements of multiple 10 ms pulses of 2.01 μm laser light incident on ex-vivo rabbit corneas

Abstract

dc:description.abstract

Current laser safety standards for multiple-pulse lasers are based primarily on modeling and the results of single-pulse studies. Previous thermal effects studies have focused on histological and visible endpoints, with only a few studies examining the actual temperatures achieved. The goal of this research was to probe the actual temperature profile produced by 2.01-micron laser pulses in the cornea. In this study the corneal temperature rise from multiple 2.01-micron Tm:YAG laser pulses was investigated using ex-vivo rabbit eyes. An infrared thermal camera employing microbolometer detectors captured surface temperature rises resulting from laser pulses. Thermal measurements were taken with single 10-ms pulses as well as two-, three-, and four-pulse sequences while holding the total energy delivered constant for the two- through four-pulse train measurements. An average temperature increase of 8.3 degrees C was observed with the single pulse at 2.8 J/cm2/pulse irradiance. For two pulses, an average temperature increase of 10.0 degrees C was observed for 2.7 J/cm2/pulse irradiance. For three pulses, an average temperature increase of 5.8 degrees C was observed for 1.9 J/cm2/pulse irradiance. For four pulses, an average temperature increase of 4.4 degrees C was observed for 1.5 J/cm2/pulse irradiance. A comparison of the data to temperatures required for denaturing proteins and the current laser safety guidelines is presented. It appears that the MPE may be overly conservative by a factor of at least 15. It is recommended that the 2.01-micron laser MPE be investigated to determine if a revision of the standard is warranted.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Environmental and Radiological Health Sciences
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kelly, Edward, author
  • Johnson, Thomas, advisor
  • Brandl, Alexander, committee member
  • Woody, Robert, committee member

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
Identifier
Kelly_colostate_0053N_10286.pdf

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kelly, Edward, author; Johnson, Thomas, advisor; Brandl, Alexander, committee member; Woody, Robert, committee member. Temperature increase measurements of multiple 10 ms pulses of 2.01 μm laser light incident on ex-vivo rabbit corneas. Masters thesis, Colorado State University. Libraries, 2011. https://doi.org/10.25675/3.019460