Abstract

dc:description.abstract

Technological developments in biomedical microsystems are opening up new opportunities to improve healthcare procedures. Swallowable diagnostic sensing capsules are an example of these. In none of the diagnostic sensing capsules, is the sensor’s first level packaging achieved via Flip Chip Over Hole (FCOH) method using Anisotropic Conductive Adhesive (ACA). In a capsule application with direct access sensor (DAS), ACA not only provides the electrical interconnection but simultaneously seals the interconnect area and the underlying electronics. The development showed that the ACA FCOH was a viable option for the DAS interconnection. Adequate adhesive formed a strong joint that withstood a shear stress of 120N/mm2 and a compressive stress of 6N required to secure the final sensor assembly in place before encapsulation. Electrical characterization of the ACA joint in a fluid environment showed that the ACA was saturated with moisture and that the ions in the solution actively contributed to the leakage current, characterized by the varying rate of change of conductance. Long term hygrothermal aging of the ACA joint showed that a thermal strain of 0.004 and a hygroscopic strain of 0.0052 were present and resulted in a fatigue like process. In-vitro tests showed that high temperature and acidity had a deleterious effect of the ACA and its joint. It also showed that the ACA contact joints positioned at around or over 1mm would survive the gastrointestinal (GI) fluids and would be able to provide a reliable contact during the entire 72hr of the GI transit time. A final capsule demonstrator was achieved by successfully integrating the DAS, the battery and the final foldable circuitry into a glycerine capsule. Final capsule soak tests suggested that the silicone encapsulated system could survive the 72hr gut transition.

Degree

thesis:*
Grantor dc:publisher
University College Cork
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jesudoss, Pio
Advisors dc:contributor.advisor
  • Mathewson, Alan
  • Stam, Frank
  • Wright, William M. D.

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • © 2011, Pio Jesudoss.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Jesudoss, P. 2011. Development and reliability of a direct access sensor using flip chip on flex technology with anisotropic conductive adhesive. PhD Thesis, University College Cork.

Chain of custody

source
Harvested from
University College Cork
Base URL
cora.ucc.ie/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jesudoss, Pio. Development and reliability of a direct access sensor using flip chip on flex technology with anisotropic conductive adhesive. University College Cork, 2011. https://hdl.handle.net/10468/3079