Control Policies for Queueing Systems with Removable Servers and Energy Considerations

Abstract

dc:description.abstract

In data centers, response time is typically of paramount concern. Systems are built with excess capacity to handle peak demand. This leads to servers idling for long periods during which time they continue to consume energy. However, it is not necessarily a simple decision to turn servers off. Servers require a warming period when they are turned on. Thus, turning a server off now can lead to long delays in the future and may not even lead to a reduction in energy usage as servers also consume energy while warming. As the financial and economic impact of energy consumption increases, new analysis is needed to identify policies that balance the trade-off between energy usage and delay performance. We study two queueing models and propose a class of simple and intuitive policies for each. First, we consider an M/M/1 queue with a removable server that dynamically chooses its service rate from a set of finitely many rates. If the server is off, the system must warm-up for a random, exponentially distributed amount of time, before it can begin processing jobs. We show under the average cost criterion, that work conserving policies are optimal. We then demonstrate that the optimal policy can be characterized by a threshold for turning on the server and the optimal service rate increases monotonically with the number of jobs in the system. Finally, we present numerical experiments to provide insights into the practicality of having both a removable server and service rate control. Next, we consider a parallel queueing system with K removable servers where jobs must be routed to a server upon arrival. We propose a class of policies for the joint routing and server power status control problem called delay-JSQ policies. Delay-JSQ policies turn additional servers on when the queue lengths at all non-empty stations exceed some threshold and route arriving jobs to the shortest non-empty queue. We show that these policies have the same stability region as \textit{join the shortest queue} routing where servers cannot turn off. We show that in the two-server setting, in the heavy traffic limit, delay-JSQ policies are optimal in terms of minimizing the holding cost rate is incurred while also incurring zero warming cost. We conclude with numerical experiments and see that delay-JSQ policies automatically and without knowledge of system parameters, adjust the number of servers to match the current capacity to the current demand

Degree

thesis:*
Name thesis:degree_name
Ph. D., Operations Research and Information Engineering
Level thesis:degree_level
Doctor of Philosophy
Discipline thesis:degree_discipline
Operations Research and Information Engineering
Grantor
Cornell University
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Badian-Pessot, Pamela Lynne
Chair dc:contributor.chair
  • Lewis, Mark E.
Committee members dc:contributor.committeemember
  • Pender, Jamol J.
  • Goldberg, David Alan
  • Down, Douglas

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Bibid
13277744
Dc Identifier Other
ProQuest Submission ID: 12106
ProQuest Publication ID: 28027107

Chain of custody

source
Harvested from
Cornell University
Base URL
ecommons.cornell.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Badian-Pessot, Pamela Lynne. Control Policies for Queueing Systems with Removable Servers and Energy Considerations. Doctor of Philosophy thesis, Cornell University, 2020. https://hdl.handle.net/1813/103075