REAL-TIME MONITORING OF CELL AND BIOINK PROPERTIES USING DIELECTRIC IMPEDANCE SPECTROSCOPY FOR EXTRUSION BIOPRINTING

Abstract

dc:description.abstract

Bioprinting, a form of additive manufacturing, uses cell-laden hydrogels to produce highly customizable constructs for applications in tissue engineering and regenerative medicine. Despite its potential, several challenges continue to impede the clinical translation of bioprinted constructs, particularly regarding reproducibility and quality assurance. Current quality control practices rely on the evaluation of critical quality attributes (CQAs) at various stages of the bioprinting workflow. These assessments are predominantly performed offline using destructive analytical techniques, which necessitate the fabrication of multiple constructs. However, reproducing identical constructs remains problematic due to the variability in bioink properties, which are time-sensitive and require extensive optimization, as well as the complex and variable nature of cell collection and processing procedures. Additionally, inconsistencies between printed constructs further complicate quality control efforts. As an alternative, the integration of biosensors directly into the bioprinting process presents a promising strategy for enabling real-time, non-destructive monitoring of CQAs, thereby enhancing process control and construct reproducibility. The application of real-time monitoring technologies in bioprinting, along with their potential uses and future directions, is explored in Chapter 1. This evaluation of the current state of the field highlighted a significant gap: the limited development of real-time, label-free methods for monitoring cellular behavior during the bioprinting process. Such monitoring is essential for ensuring the consistency and clinical viability of bioprinted constructs. In response to this need, Chapter 2 demonstrates the feasibility of using dielectric impedance spectroscopy as an in-line method for assessing cell concentration and viability directly from a syringe. To further assess the utility of this approach within a bioprinting context, Chapter 3 examines how variations in alginate bioink properties affect the real-time detection of cells. Finally, to expand upon the applications for this technology, Chapter 4 presents modifications to the electrode housing and geometry, which resulted in improved manufacturability and heightened sensitivity to a wide range of cell concentrations.

Degree

thesis:*
Name thesis:degree_name
Ph. D., Biomedical Engineering
Level thesis:degree_level
Doctor of Philosophy
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
Cornell University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Matavosian, Alicia
Chair dc:contributor.chair
  • Bonassar, Lawrence
Committee members dc:contributor.committeemember
  • Delco, Michelle
  • Shepherd, Robert

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Attribution 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Bibid
17422671
Dc Identifier Other
ProQuest Submission ID: 15186
ProQuest Publication ID: 32169565

Chain of custody

source
Harvested from
Cornell University
Base URL
ecommons.cornell.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Matavosian, Alicia. REAL-TIME MONITORING OF CELL AND BIOINK PROPERTIES USING DIELECTRIC IMPEDANCE SPECTROSCOPY FOR EXTRUSION BIOPRINTING. Doctor of Philosophy thesis, Cornell University, 2025. https://hdl.handle.net/1813/120909