Back to search

Cornell University

Effects Of Total Shoulder Arthroplasty On Glenohumeral Kinematics And Mechanics

Abstract

dc:description.abstract

Glenoid component loosening is the primary reason for failure after a total shoulder arthroplasty (TSA) accounting for 32% of complications post-surgery. The design of the glenoid implant, specifically the degree of conformity or radial mismatch between the bearing surface of the glenoid and humeral components, allows for posterior translation and has been shown to affect glenoid loosening. Existing theories for the failure mechanism are conflicting, suggesting that failure occurs in the bone, cement, or interface, with no agreement on the mechanism that causes glenoid loosening. The focus of this thesis is to obtain a fundamental understanding of glenohumeral joint translations and load transfer in the bone-implant system after a TSA. First, we studied the posterior glenohumeral translations observed clinically using a six degree of freedom computational model of the shoulder. We found that posterior translation increased as a function of radial mismatch, and the increase in posterior translation was explained by the increase in force in the infraspinatus muscle. Secondly, using a finite element model of the healthy scapula, we determined that after a cemented TSA, stress shielding was possible because load bypassed the cancellous bone region and was transferred directly to the stiff cortical bone when the implant pegs were present. Additionally, the cement was more likely to failure during eccentric and high magnitude loading. Finally, using finite element models of an osteoarthritic scapula, we showed that stress shielding and cement failure was more likely in the corrected osteoarthritic glenoid compared to the healthy and retroverted osteoarthritic glenoids during eccentric loading. These findings question the common surgical practice of correcting for glenoid retroversion prior to reconstruction. Furthermore, the reconstructed osteoarthritic glenoid was less sensitive to peg length than the healthy glenoid demonstrating that shorter pegs, requiring less bone resection, may be used in osteoarthritic patients.

Degree

thesis:*
Name thesis:degree_name
Ph. D., Mechanical Engineering
Level thesis:degree_level
Doctor of Philosophy
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor
Cornell University
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Patel, Radhika
Chair dc:contributor.chair
  • Gao, Yingxin
Committee members dc:contributor.committeemember
  • Wright, Timothy M.
  • Hernandez, Christopher J.

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Bibid
8641222

Chain of custody

source
Harvested from
Cornell University
Base URL
ecommons.cornell.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Patel, Radhika. Effects Of Total Shoulder Arthroplasty On Glenohumeral Kinematics And Mechanics. Doctor of Philosophy thesis, Cornell University, 2014. https://hdl.handle.net/1813/37119