Back to search

Cornell University

Sample saving techniques for solution X-ray scattering studies of biological macromolecules

Abstract

dc:description.abstract

Small-angle X-ray scattering (SAXS) provides structural information about biomolecules in solution. The resulting insight increases our understanding of biological processes and can aid in structure-based drug design. However, SAXS experiments require tens of microliters of sample at mg/mL concentrations, making the technique unsuitable for molecules that cannot be produced in large quantity. This dissertation introduces three new techniques for sample efficient SAXS experiments. The first details the fabrication and use of fixed path length sample cells for cryoSAXS experiments, as well as their challenges. The cells have rigid walls with low scatter and high X-ray transmission, and allow SAXS measurements from less than two microliters of sample. Although fractures in the vitrified samples produce irreproducible scatter at the lowest angles, the technique is robust and applicable to molecules with maximum dimension less than ~160 Å. The second method implements a coaxial, continuous flow diffusive mixer for low sample volume time-resolved SAXS on the 10 ms - 3 s timescale. The mixer’s geometry allows the use of a larger, higher flux beam than is compatible with most continuous flow SAXS mixers, shortening the acquisition time and reducing sample consumption. A custom beamline setup reduces background scatter to further improve data quality. Each measurement uses less sample than a conventional static SAXS experiment. A study of RNA folding initiated by Mg2+ is presented as an example of the utility of this technique. The final method employs a chaotic advection mixer for time-resolved SAXS measurements on slowly diffusing systems. This device incorporates a miniaturized static mixer to efficiently mix two liquids in the laminar flow regime. An improved beamline setup delivers a higher flux beam than can be used with the diffusive mixer, minimizing acquisition time and sample consumption. This mixer uses an order of magnitude less sample than turbulent flow SAXS mixers, and about twice the sample needed for a conventional static SAXS measurement. Time-resolved SAXS measurements of the binding of trypsin and aprotinin, a well-studied protein pair, are presented as a proof of principle.

Degree

thesis:*
Name thesis:degree_name
Ph. D., Applied Physics
Level thesis:degree_level
Doctor of Philosophy
Discipline thesis:degree_discipline
Applied Physics
Grantor
Cornell University
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Katz, Andrea Michelle
Chair dc:contributor.chair
  • Pollack, Lois
Committee members dc:contributor.committeemember
  • Craighead, Harold G.
  • Gruner, Sol Michael

Subjects

dc:subject × 8

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Bibid
10489657
Dc Identifier Other
ProQuest Submission ID: 11028
ProQuest Publication ID: 10846600

Chain of custody

source
Harvested from
Cornell University
Base URL
ecommons.cornell.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Katz, Andrea Michelle. Sample saving techniques for solution X-ray scattering studies of biological macromolecules. Doctor of Philosophy thesis, Cornell University, 2018. https://hdl.handle.net/1813/59561