Back to search

Universidade da Coruna

Recambio valvular aórtico aislado en pacientes mayores de 75 años mediante abordaje mínimamente invasivo y bioprótesis sin sutura

Abstract

dc:description.abstract

[Abstract] Introduction Study on the influence of sutureless aortic valvular bioprosthesis on the postoperative inflammatory response and on the clinical impact following the implementation of a minimally invasive surgery program (MIS) using sutureless bioprosthesis. Methods Preliminary phase: Randomized clinical trial. Group P (sutureless bioprosthesis through CMI, n = 20), Group C (conventional bioprosthesis through MIS, n = 20). Determination of biomarkers of inflammatory response were obtained. Sutureless-MIS program assessment: Restrospective study. Group A: Sutureless bioprosthesis through MIS (n = 108). Group B: Conventional bioprosthesis through full sternotomy (n = 115). Results Preliminary phase: Randomized clinical trial. Group P (sutureless bioprosthesis through CMI, n = 20), Group C (conventional bioprosthesis through MIS, n = 20). Determination of biomarkers of inflammatory response were obtained. Sutureless-MIS program assessment: Restrospective study. Group A: Sutureless bioprosthesis through MIS (n = 108). Group B: Conventional bioprosthesis through full sternotomy (n = 115). Results Preliminary phase: Reduction of surgical times in Group P versus group C, associated with lower postoperative levels of IL-6 (p = 0.021). Sutureless-MIS program assessment: Perioperative mortality was 1/223 patients, belonging to group B. Surgical times, ICU and hospital stays, transfusional requirements and postoperative aortic valve gradients were lower in group A (p < 0.05). Group A showed a higher rate of pacemaker implantation (p = 0.051). Conclusion The MIS using sutureless aortic bioprosthesis allowed a significant reduction in surgical times associated with lower levels of IL-6 and was shown as a safe and effective technique, providing clinical benefits when compared to conventional surgery.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Estévez-Cid, Francisco
Advisor dc:contributor.advisor
  • Bautista-Hernández, Víctor

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
  • Atribución-NoComercial-SinDerivadas 3.0 España
Language dc:language.iso
spa

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2183/21094

Chain of custody

source
Harvested from
Universidade da Coruna
Base URL
ruc.udc.es/rest/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Estévez-Cid, Francisco. Recambio valvular aórtico aislado en pacientes mayores de 75 años mediante abordaje mínimamente invasivo y bioprótesis sin sutura. 2018. https://hdl.handle.net/2183/21094