Back to search

Cranfield University

Development of baseline stability in an electromagnetic flowmeter for dielectric liquids

Abstract

dc:description.abstract

This thesis is concerned with the development of a prototype electromagnetic flowmeter for dielectric liquids. A initial prototype flowmeter is tested in laboratory conditions with a liquid of low conductivity, the conclusion of these initial tests being that the stability of the flowmeter is below that required for its design applications. This lack of stability is a problem reported on several occasions in similar projects involving electromagnetic flowmeters for dielectric liquids. Therefore the main body of the work is spent investigating the causes of instability and trying to redress the necessary problems in order that a viable working prototype is developed. Problems of thermal instability, electrostatic and electromagnetic shielding are addressed along with the causes and effects of all the major noise and unwanted signals experienced in such a system. A new prototype is developed incorporating stability driven improvements. This new design is rigorously tested and assessed. The stability of the meter is considered with respect to its flow related output. Several parameters of operational stability are given in the examples considered. A final assessment is then made of the flowmeters baseline performance and a account of any remaining instability is given with respect to the issue developed throughout the thesis. The conclusions indicate that the electromagnetic flowmeter for dielectric fluids does produce a linear output based on Faraday's law of induction. They also indicate that the instability experienced previously can be broken into its constituent parts and each contributor accounted for and reduced, working towards the ideal totally stable flowmeter.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Durcan, L. P.
Advisors dc:contributor.advisor
  • Hemp, J.
  • Sanderson, M. L.

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 1998. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://dspace.lib.cranfield.ac.uk/handle/1826/10720

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation