Back to search

Cranfield University

Rotating stall inception in fans of low hub-tip ratio

Abstract

dc:description.abstract

An investigation was carried out to study the process of rotating stall inception in a low hub-tip ratio fan. Such fans are expected, based on an elementary analysis, to stall from the root. However, experimental evidence had led to the belief that the fans stalled from the tip. The effects of streamtube contraction were first studied and this was followed by an experimental investigation on an isolated rotor, with successive build modifications to increase the likelihood of rotating stall inception occurring at the root. A computer based streamline curvature method was used to study the effects of streamtube contraction and streamtube diffusion that commonly occur when a fan is operated at flows below its' design flow rate. The results indicated a reduced expectation for the root to stall first when compared to a simple 2-D flow analysis. Experimental measurements were then carried out to determine how the experimental local characteristics differed from the predicted characteristics. It was apparent that real fluid effects tended to steepen the root characteristic, thus enhancing the stability of the root. The tip characteristics tended to droop and become less stable. The enhancement of the root stability was also seen in the profiles of deviation angle. The axial Velocity contours at the rotor exit supported the conclusion that the root stability enhancement was caused by "centrifuging". To determine the actual radial location of rotating stall inception, an array of hot wires was used to record events during the inception transient. Inception was first detectable at the tip. This tip stalling behaviour persisted for all the build modifications. Measurements of unsteady pressure were also made to study the movement of the overall operating point since it was felt that this could continuously alternate between a pair of closely spaced characteristics. The results indicated that the fan operated along a unique characteristic. The overall conclusion was that a low hub-tip ratio fan shows a strong reluctance to stall at the root due to "centrifuging" of the blade boundary layer. The inception process appears to be dominated by events in the tip region.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Soundranayagam, M.
Advisor dc:contributor.advisor
  • Elder, R. L.

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 1991. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://dspace.lib.cranfield.ac.uk/handle/1826/10753

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Soundranayagam, M.. Rotating stall inception in fans of low hub-tip ratio. Cranfield University, 1991. http://dspace.lib.cranfield.ac.uk/handle/1826/10753