Back to search

Cranfield University

Heat transfer modelling, optimisation and monitoring of flashlamp- assisted automated tape placement.

Abstract

dc:description.abstract

This study aims to develop tools for the design, optimisation and control of automated tape placement (ATP) that integrates flashlamp heating. A thermo-optical simulation of ATP is developed, combining a 2D finite element model of the heat conduction with 3D ray tracing analysis. The methodology is validated against measurements acquired during ATP trials of AS4 carbon/PEEK composites, presenting deviations up to 20°C. Flashlamp operation at low frequency and long pulses (25 Hz /4.75 ms) results in up to 150°C higher irradiation temperatures and increased thermal penetration depth, 100 over 50 μm, compared to high frequency and short pulses (100 Hz/1.1 ms) or continuous operation. Consolidation temperatures under the roller are identical for pulsing scenarios of equivalent average power, including continuous operation. To increase computational efficiency, an 1D simulation of ATP is put forward comprising distinct models representing the tow, deposited material, and consolidated stack with transfer of temperature information to ensure field continuity. The 1D solution requires only 1-2% of the computational effort of the 2D model with a minor trade-off in accuracy, up to 14°C. Based on the efficient 1D solution, an optimisation scheme of ATP is developed by integrating models of material degradation, interfacial bonding and a Genetic Algorithm. The optimisation scheme identifies the Pareto front of the multi-objective problem accurately in 25% of the computational effort required for an exhaustive search. Strong trade-offs exist between bonding, thermal degradation and productivity, limiting the average bonding value in the stack to 0.35 before matrix degradation exceeds the 1% threshold typically set for aerospace applications. A monitoring strategy for ATP of thermoplastic prepregs is proposed combining 1D analytical solutions and temperature data acquired on the tool side of the deposited material, allowing estimation of nip point temperatures in real time. The method integrates an inverse solution to determine the heater power input from temperature data and enhance the nip point estimation accuracy. The monitoring scheme presents good accuracy for a wide range of velocities, substrate thickness and tooling materials, with an average error of 15°C even in the presence of significant measurement noise.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Danezis, Anastasios
Advisors dc:contributor.advisor
  • Skordos, Alexandros A.
  • Williams, David

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 2023. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://dspace.lib.cranfield.ac.uk/handle/1826/20253

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Danezis, Anastasios. Heat transfer modelling, optimisation and monitoring of flashlamp- assisted automated tape placement.. Cranfield University, 2023. https://dspace.lib.cranfield.ac.uk/handle/1826/20253