Back to search

Cranfield University

The influence of surface determination in x-ray computed tomography

Abstract

dc:description.abstract

X-ray computed tomography (XCT) is a non-destructive technique that enables the dimensional inspection of the internal and external features of modern components. All dimensional attributes, including form, size and surface texture, are derived from the surface of the component, therefore, surface determination (SD) is a critical step in X-ray computed tomography (XCT) for dimensional metrology. Threshold-based and gradient-based algorithms are widely used. However, these algorithms are often sensitive to systematic errors and can be largely influenced by the input parameters selected by operators. Current research gaps include the limited knowledge related to the quantifiable impact of SD algorithms on the traceability of the XCT geometric measurements and to the SD algorithm robustness to threshold setting. It was postulated here that Marker-controlled watershed (MCW), successfully applied in the medical field, can overcome the potential threshold errors encountered with current SD algorithms and provide robust results even in the presence of typical XCT errors. As a result, this thesis presents the development of a robust SD algorithm for XCT based on the MCW method, which combined weighted gradient voxel refinement and automated marker generation. The validation and comparison of MCW were accomplished by employing calibrated workpiece for experimental XCT scanning, and simulation. The work has further evaluated the performance of MCW algorithm and two commonly applied SD algorithms, Canny and ‘advanced mode in VGStudio’ (VG) algorithms, under beam hardening and noise effect. SD thresholding parameters were optimised by Taguchi methods when evaluating different types of surface conditions, including smooth and rough surfaces. Canny presented the worst performance during the measurement of rough surfaces but performed well in smooth surface measurement cases. VG performed worst in bi-directional measurement under the influence of beam hardening but successfully computed the rough surface when beam hardening was corrected. The proposed MCW demonstrated that it is an all-rounded algorithm. Compared to other surface determination algorithms, the MCW algorithm presented consistent results with little influence from the beam hardening, noise and threshold settings. This demonstrates a great potential that the proposed SD algorithm can be fully automated in XCT.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yang, Xiuyuan
Advisors dc:contributor.advisor
  • Giusca, Claudiu
  • Sun, Wenjuan

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 2022. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://dspace.lib.cranfield.ac.uk/handle/1826/24258

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Yang, Xiuyuan. The influence of surface determination in x-ray computed tomography. Cranfield University, 2022. https://dspace.lib.cranfield.ac.uk/handle/1826/24258