Back to search

Cranfield University

Optical metrology to support the next generation of nanopositioning

Abstract

dc:description.abstract

This thesis develops methods for the analysis and elimination of non-linearities, defined as errors in the measured displacement that are periodic with some harmonic of the illuminating wavelength, in homodyne displacement measuring optical interferometers. A particular focus is placed on phase-quadrature coating based interferometers. A novel modelling technique is described, allowing the effects of cavity formation within networks of polarising optics to be analysed. This modelling technique is applied to investigate the sources higher order non-linearities introduced by unwanted cavity formation within the optics of the NPL plane plane mirror differential interferometer. Some non-linearities may be eliminated through improved optical design, however, this is not always possible, or practical. Three novel correction algorithms are therefore proposed, aiming to correct for non-linearities in situations where existing correction algorithms fail. The first, the two-wavelength non-linearity correction aims to correct for higher order non-linearities in cases where the displacement covers several optical fringes. Compared to a standard Heydemann ellipse fitting correction, the two-wavelength approach is shown to reduce estimated residual non-linearity amplitude from 84 pm to 11 pm. The second algorithm, the multiple intensity reference correction, aims to correct for non-linearities in cases where the displacement covers a small portion of the optical fringe. This algorithm is shown to reduce the amplitude of elliptical non-linearity harmonics to below the 10 pm level. Finally, the measurement arm normalisation correction also aims to correct for certain sources of higher order non-linearities, but reduced optical, electrical and data processing complexity as compared to the two-wavelength correction. Based on the findings of modelling work in combination with experimental non-linearity measurements, an improvement to an existing NPL interferometer design, utilising the measurement arm normalisation correction, is developed and tested. Peak-to-peak residual non-linearities of (23:0 ± 0:6) pm are achieved, reduced from (56:8 ± 0:4) pm by application of the measurement arm normalisation algorithm.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bridges, Angus
Advisors dc:contributor.advisor
  • Tatam, Ralph P.
  • Kissinger, Thomas
  • Yacoot, Andrew

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 2022. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://dspace.lib.cranfield.ac.uk/handle/1826/24473

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bridges, Angus. Optical metrology to support the next generation of nanopositioning. Cranfield University, 2022. https://dspace.lib.cranfield.ac.uk/handle/1826/24473