Back to search

Cranfield University

Analysis of gas turbine compressor fouling and washing on line

Abstract

dc:description.abstract

This work presents a model of the fouling mechanism and the evaluation of compressor washing on line. The results of this research were obtained from experimental and computational models. The experimental model analyzed the localization of the particle deposition on the blade surface and the change of the surface roughness condition. The design of the test rig was based on the cascade blade arrangement and blade aerodynamics. The results of the experiment demonstrated that fouling occurred on both surfaces of the blade. This mechanism mainly affected the leading edge region of the blade. The increment of the surface roughness on this region was 1.0 μm. This result was used to create the CFD model (FLUENT). According to the results of the CFD, fouling reduced the thickness of the boundary layer region and increased the drag force of the blade. The model of fouling was created based on the experiment and CFD results and was used to calculate the engine performance in the simulation code (TURBOMATCH). The engine performance results demonstrated that in five days fouling can affect the overall efficiency by 3.5%. The evaluation of the compressor washing on line was based on the experimental tests and simulation of the engine performance. This system demonstrated that it could recover 99% of the original blade surface. In addition, this system was evaluated in a study case of a Power Plant, where it proved itself to be a techno-economic way to recover the power of the engine due to fouling. The model of the fouling mechanism presented in this work was validated by experimental tests, CFD models and information from real engines. However, for further applications of the model, it would be necessary to consider the specific conditions of fouling in each new environment.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vigueras Zuniga, Marco Osvaldo
Advisor dc:contributor.advisor
  • Pilidis, Pericles

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 2007. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1826/2448

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Vigueras Zuniga, Marco Osvaldo. Analysis of gas turbine compressor fouling and washing on line. Cranfield University, 2007. https://hdl.handle.net/1826/2448