Back to search

Cranfield University

Volatile diagnostic techniques for ventilator associated pneumonia

Abstract

dc:description.abstract

Ventilator associated pneumonia (VAP) is a significant challenge for the Intensive Care doctors worldwide. It is both difficult to diagnose accurately and quickly and to treat effectively once the diagnosis has been established. Current diagnostic microbiological methods of diagnosis can take up to 48 hours to yield results. Early diagnosis and treatment remain the best way of improving outcome for patients with VAP. In this study we look at novel diagnostic techniques for VAP. Electronic nose (Enose) technology was used to identify to identify the presence of microorganisms in bronchoalveolar lavage (BAL) fluid samples taken from the respiratory tracts of ventilated patients. The results were compared with standard microbiological culture and sensitivities. The Enose was able to discriminate 83% of samples into growth or no growth groups on samples grown in the lab. When the technique was employed to samples taken directly from patients the accuracy fell to 68.2%. This suggests that patient related factors may be reducing the accuracy of the Enose classification. The use of antimicrobial drugs prior to patient sampling is likely to have played a major role. The second part of this study used Gas Chromatography-Mass Spectrometry (GC-MS) analysis of patient’s breath in an attempt to identify patients with VAP. Breath samples were taken at the same time as the bronchoalveolar lavage samples described above. The use of this technique did show differences between the breath samples of patients who did not have any microbiological growth from their BAL samples and those that did. Leave one out cross validation of a PC fed LDA model showed 84% correct classification between healthy volunteers, no growth and growth groups. Finally, we evaluated the Breathotron, which is a breath analysis device designed and built at Cranfield Health. It allows for analysis of breath samples using a single sensor system as opposed to a sensor array employed in traditional Enose devices. This allows it to be more portable and cheaper to build. The Breathotron also allows collection of breath onto sorbent cartridges for GC-MS analysis. Its single sensor did not allow for accurate discrimination between samples.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Humphreys, Martyn Lee
Advisors dc:contributor.advisor
  • Kendall, Catherine
  • Magan, Naresh
  • Barr, H.

Rights

dc:rights
Statement dc:rights
  • © Cranfield University 2010. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://dspace.lib.cranfield.ac.uk/handle/1826/5738

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Humphreys, Martyn Lee. Volatile diagnostic techniques for ventilator associated pneumonia. Cranfield University, 2010. http://dspace.lib.cranfield.ac.uk/handle/1826/5738