Back to search

Cranfield University

Design of molecularly imprinted polymers for sensors and solid phase extraction

Abstract

dc:description.abstract

This thesis presents broadly the applications of molecularly imprinted polymers in sensors and solid phase extraction. Sensors for creatine and creatinine have been reported using a novel method of rational design of molecularly imprinted polymers (MIPs), and solid phase extraction of aflatoxin-B 1 has also been described in the thesis. A method for the selective detection of creataine and creatinine is reported in this thesis, which is based on the reaction between polymerised hemithioacetal, formed by allyl mercaptan, o-phthalic aldehyde, and primary amine leading to the formation of fluorescent isoindole complex. This method was demonstrated for the detection of creatine using creatine-imprinted MIPs. Since MIPs created using traditional methods were unable to differentiate between creatine and creatinine, a new approach to the rational design of a MIP selective for creatinine was developed using computer simulation. A virtual library of functional monomers was assigned and screened against the target molecule, creatinine, using molecular modeling software. The monomers giving the highest binding score were further tested using simulated annealing in order to mimic the complexation of the functional monomers with template in the monomer mixture. The result of this simulation gave an optimised MIP composition. The computationally designed polymer demonstrated superior selectivity in comparison to the polymer prepared using traditional approach, a detection limit of 25 μM and good stability. The 'Bite-and- Switch' approach combined with molecular imprinting can be used for the design of assays and sensors, selective for amino containing substances. MEP for the selective binding properties for aflatoxin-B 1 was prepared using the computational approach. The results obtained demonstrate that the MISPE offers a simple, convenient and a rapid methodology for solid phase extraction of aflatoxin-B 1 even at very low concentrations of 2 ppb. The commercially available C-18 cartridges were able to recover only about 52% of aflatoxin-B 1 at concentrations of 2 ppb when compared with almost complete recovery by the MIP. We have proved here that, MIPs as a solid phase extraction materials offer important and practical advantages with respect to other solid phase extraction methodologies.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Subrahmanyam, Sreenath
Advisors dc:contributor.advisor
  • Turner, Anthony P. F.
  • Piletsky, Sergey A.

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 2002. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://dspace.lib.cranfield.ac.uk/handle/1826/7576

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Subrahmanyam, Sreenath. Design of molecularly imprinted polymers for sensors and solid phase extraction. Cranfield University, 2002. http://dspace.lib.cranfield.ac.uk/handle/1826/7576