Fouling of a plate heat exchanger by cheese whey solutions

Abstract

dc:description.abstract

A plate heat exchanger rig was developed at Dublin City University to study fouling of plate heat exchangers using cheese whey solutions. The rig consisted of an Alfa-Laval plate heat exchanger, 316 stainless steel pipework, pressure and temperature measurement and was temperature controlled with all information logged via an Anville data acquisition system. Cheese whey solutions of various concentration were passed through the plate heat exchanger for periods of up to four hours. The effect of flowrate, temperature, whey concentration and cleaning on fouling resistance were investigated. Increasing the processing temperature was found to increase the rate of fouling Maximum deposition on the plates of the heat exchanger was found to occur at low whey flowrates Increasing whey concentration was found to increase the rate of fouling. An induction period was noted and asymptotic fouling found to occur at low flowrates and high temperatures. Cleaning of the plates of the heat exchanger was found to significantly affect the rate of fouling.

Degree

thesis:*
Name dc:type.qualificationname
msc
Level dc:type.qualificationlevel
masters
Grantor dc:publisher.institution
Dublin City University
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Corcoran, Brian

Rights

Language dc:language
en

Chain of custody

source
Harvested from
Dublin City University
Base URL
doras.dcu.ie/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Corcoran, Brian. Fouling of a plate heat exchanger by cheese whey solutions. masters thesis, Dublin City University, 1997.