Back to search

Dublin City University

Characterisation of the performance of an absorbable magnesium stent by experimental and numerical analysis

Abstract

dc:description.abstract

Magnesium stents are a promising candidate in the emerging field of bioabsorbable stents and could obviate many of the limitations of current permanent stent platforms such as stent thrombosis and in-stent restenosis. In this study, viable magnesium stents were manufactured from WE43 magnesium alloy precursor tubes by a combination of laser cutting and chemical and plasma-based surface treatments. The mechanical and corrosion performance of the stent was elucidated via experiments. It was shown that the plastic strain that is induced in the stent struts during the deployment procedure has a critical influence in directing both the kinetics and the nature of subsequent corrosion processes in the alloy. The deployment and scaffolding characteristics of the stent were determined and contrasted with those of a commercial stainless steel stent. The magnesium stent was shown to support significantly higher levels of cyclic strain amplitude which plays a crucial role in reducing in-stent restenosis. This study provided new insights into the performance of a current magnesium stent design and material and demonstrated the influence of deployment induced corrosion on the long-term scaffolding ability of the stent. A finite element based phenomenological corrosion model was developed and calibrated based on the results of the corrosion experiments. A plastic strain parameter was introduced in the modelling framework to account for the effects of plastic strain on corrosion behaviour. The model was found to be capable of predicting the experimentally observed mass loss profile and the temporal corrosion-induced reduction in the radial stiffness of the stent.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Dublin City University
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Galvin, Emmet

Rights

Language dc:language
en

Chain of custody

source
Harvested from
Dublin City University
Base URL
doras.dcu.ie/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Galvin, Emmet. Characterisation of the performance of an absorbable magnesium stent by experimental and numerical analysis. doctoral thesis, Dublin City University, 2014.