Back to search

University of Denver

Development of a Clinical Marker-less Motion Capture System for Patient Monitoring

Abstract

dc:description.abstract

The ability to understand human movement is beneficial for deciding surgical procedures, tracking disease progression over time and helping with patient rehabilitation. The current gold-standard for collecting human movement is the use of 3-dimensional marker-based systems. Several studies have presented the many limitations to the current gold-standard that reduces the number of people who are able to benefit from a gait analysis. Those limitations in the current gold-standard include the requirements of large laboratory space, costly equipment, long instrumentation and collection time, and the potential for motion artifact from markers being placed on the skin. The purpose of this study is to create a marker-less motion capture system using the newly–released Kinect Azure cameras from Microsoft. The study aims to validate the new system against the gold-standard. A validation of a four Kinect Azure camera system was conducted with 10 subjects completing over ground walking trials at a self-selected pace, sit-to-stand, lunge, and step up/down while Kinect and 3D marker-based data were collected simultaneously. The data was synchronized and cut to a single activity cycle where joint angles and spatio-temporal measures were compared between the two systems. Walking speed and stride length were highly correlated between the two systems with r-values >0.9 and p-values <0.001. The average difference in maximum knee flexion angle between the two systems is 2.84° with a r=0.785 and p-value <0.001. A 3D point cloud was generated from the four Kinect Azure camera system to generate a surface mesh. The 3D mesh was used to provide a better understanding of body habitus than current BMI.

Degree

thesis:*
Name thesis:degree_name
M. S.
Level thesis:degree_level
Masters Thesis

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Eustace, Abigail
Contributors dc:contributor
  • Paul Rullkoetter
  • Chadd W. Clary
  • Barry Zink

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • <p>Copyright is held by the author. User is responsible for all copyright compliance.</p>
  • Abigail Eustace
Language dc:language
en

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.du.edu/etd/1760

Chain of custody

source
Harvested from
University of Denver
Base URL
digitalcommons.du.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Eustace, Abigail. Development of a Clinical Marker-less Motion Capture System for Patient Monitoring. Masters Thesis thesis, https://digitalcommons.du.edu/etd/1760