Back to search

University of Denver

An Accuracy and Precision Analysis of the VELYS™ Robotic Assisted Solution for Total Knee Arthroplasty

Abstract

dc:description.abstract

Total knee arthroplasty (TKA) is a procedure where the arthritic surfaces of the knee is removed and replaced with a combination of metal and polymer implants that recreates the joint line to restore function and quality of life. Implant alignment is important in the success of a TKA. Modern day conventional instrumentation can be cumbersome in the operating room and can be inaccurate when resecting bone and aligning implants. Patients with large errors in resections and implant orientation are more prone to experience mechanical failures with their TKA. Mechanical failures in primary TKA require revision surgeries which can lead to further iatrogenic effects. New technology has been created to reduce these errors such as computer-aided surgery and robotic assisted total knee arthroplasty (RATKA). The purpose of this study was to measure the accuracy and precision of femoral and tibial osteotomies and implant alignment between RATKA and conventional total knee arthroplasty (CTKA). The results showed that coronal plane resection errors improved from 1.39° ± 0.95° to 0.65° ± 0.50° and implant alignment absolute errors improved from 1.42° ± 1.15° to 0.91° ± 0.83° for RATKA cases. Improvements were also seen for sagittal plane implant alignment and femoral relative resections for RATKA cases. Other measures reported non-inferiority and there was no statistical difference in the flatness of the proximal resection (p = 0.36) between CTKA and RATKA.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters Thesis

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Doan, Gary
Contributors dc:contributor
  • Chadd W. Clary
  • Peter J. Laz
  • Mark E. Siemens

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • <p>Copyright is held by the author. User is responsible for all copyright compliance.</p>
  • Gary Doan
Language dc:language
en

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.du.edu/etd/1909

Chain of custody

source
Harvested from
University of Denver
Base URL
digitalcommons.du.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Doan, Gary. An Accuracy and Precision Analysis of the VELYS™ Robotic Assisted Solution for Total Knee Arthroplasty. Masters Thesis thesis, https://digitalcommons.du.edu/etd/1909