University of Denver
Structural and Hemodynamic Analysis of Transcatheter Aortic Valves
Abstract
dc:description.abstractThe transcatheter aortic valve replacement (TAVR) procedure has become a well-established procedure for high, intermediate-risk, and low-risk patients. However, there is limited clinical data on the TAV's long-term durability, unlike SAV devices. Computational simulations can be an alternative way to evaluate the TAV devices. This dissertation aims to conduct structural and hemodynamic analyses on the TAV devices under different conditions using computational simulation approaches. Initially, the impact of the bicuspid aortic valve on the TAV devices was evaluated. The result indicated that the CoreValve-like supra-annular self-expandable device was likely to have increased stress and strain on the leaflet when it was elliptically deployed. The impact on the intra-annular balloon-expandable design was minor in the clinic. Subsequently, the effect of regional under-expansion on the supra-annular self-expandable device was studied. The simulations showed that the reduced leaflet angle could impair leaflet motion and increase stress. The small-angle leaflet was likely to fail over time. The hemodynamic analysis was conducted on both super-annular and intra-annular designs in pulse duplicator models. The result proves that the thrombosis is likely to initiate at the fixed edge of the intra-annular design and lower belly region of the supra-annular design. Most of the blood within the neo-sinus region in the supra-annular design could be washed out within one cardiac cycle. However, the blood near the fixed could accumulate and increase thrombosis risk. Furthermore, the BASILICA procedure was investigated with an intra-annular design in a patient-specific geometry. This procedure could considerably reduce the blood stasis on the leaflets. The reduction can be as high as13.2 % on the left coronary leaflet. The presented works showed that the design improvement should be focused on the region at the lower belly region in the supra-annular design and the fixed edges in the fixed edge of the intra-annular design to improve the long-term durability of the TAV devices. The BASILICA could be an alternative way for physicians to reduce the thrombosis risk.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Dissertation
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Qiu, Dong
- Contributors dc:contributor
-
- Ali N. Azadani
- Yan Qin
- Yun-bo Yi
- Chadd Clary
Subjects
dc:subject × 10Rights
dc:rights- Statement dc:rights
-
- <p>Copyright is held by the author. User is responsible for all copyright compliance.</p>
- Dong Qiu
- Language dc:language
- en
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.du.edu/etd/2074