Back to search

University of Denver

Compact 1 GHz Electron Paramagnetic Resonance Spectrometers for Preclinical Imaging Studies

Abstract

dc:description.abstract

Magnetic resonance is one of the most generally useful scientific techniques. New horizons of understanding are revealed as technological advances make possible explorations of nuclear spins and electron spins at higher and lower magnetic fields and electromagnetic frequencies. While the greatest current effort is on ever higher magnetic fields and microwave frequencies, both in nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR), the Eaton lab focusses on developing high signal-to-noise performance EPR at low microwave frequencies. EPR provides information about O2, pH, viscosity, glutathione concentrations, and reactive oxygen species in living organisms that MRI cannot. To yield clinically or preclinically relevant images good signal-to-noise (S/N) is required. It is hypothesized that new EPR instrumentation is needed for this at 1 GHz which should provide the required S/N and penetrate the body to the desired depth. The Eaton lab initiated and developed pulsed microwave and rapid magnetic field scan imaging at 250 MHz and then 700 MHz. The focus of this thesis is the step from 700 MHz to 1 GHz. The application of rapid scan imaging at 1 GHz to preclinical imaging of mouse lungs and diabetic wound healing at the Anschutz Medical Center has been demonstrated. To further boost the signal to noise a technique that rapidly modulates the magnetic field called ‘rapid scan’ is employed. A key feature of the rapid scan spectrometer and imager is the achievement of the highest S/N of any low-frequency EPR spectrometer that has been reported. Pulsed spectrometers have advantages for oximetry experiments in particular, so an initial investigation was done into the design of this type of spectrometer at 1 GHz. Together, these rapid scan and pulse spectrometers will establish a foundation for the development of future high-sensitivity preclinical and later clinical EPR imaging. Construction of both of these instruments required extensive computer programing in MATLAB and interfacing high-performance digitizers to the EPR signal data-acquisition path. The codes produced are provided.

Degree

thesis:*
Name thesis:degree_name
Ph.D. in Chemistry and Biochemistry
Level thesis:degree_level
Dissertation

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hovey, Tanden A.
Contributors dc:contributor
  • Sandra S. Eaton
  • Gareth R. Eaton
  • Dali Sun
  • Scott Horowitz
  • Brian Majestic
  • Brady Worrell

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • <p>Copyright is held by the author. User is responsible for all copyright compliance.</p>
  • Tanden A. Hovey
Language dc:language
English (eng)

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Denver
Base URL
digitalcommons.du.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hovey, Tanden A.. Compact 1 GHz Electron Paramagnetic Resonance Spectrometers for Preclinical Imaging Studies. Dissertation thesis, https://doi.org/10.56902/ETDCRP.2026.156