Back to search

Duke University

Label-free Biodetection with Individual Plasmonic Nanoparticles

Abstract

dc:description.abstract

<p>The refractive index sensitivity of plasmonic nanoparticles is utilized in the development of real-time, label-free biodetection. Analyte molecules that bind to receptor-conjugated nanoparticles cause an increase in local refractive index that in turn induces an energy shift in the optical resonance of the particle. Biomolecular binding is quantified by quantitatively measuring these resonance shifts. This work describes the application and optimization of a biomolecular detection system based on gold nanorods as an optical transducer.</p> <p>A microspectroscopy system was developed to collect scattering spectra of single nanoparticles, and measure shifts of the spectra as a function of biomolecular binding. The measurement uncertainty of LSPR peak shifts of the system was demonstrated to be 0.3 nm. An analytical model was also developed that provides the optimal gold nanorod geometry for detection with specified receptor-analyte pair. The model was applied to the model biotin-streptavidin system, which resulted in sensing system with a detection limit of 130 pM - an improvement by four orders of magnitude over any other single-particle biodetection previously presented in the literature.</p> <p>Alternative optical detection schemes were also investigated that could facilitate mulitplexed biosensing. A theoretical model was built to investigate the efficacy of using a multi-channel detector analogous to a conventional RGB camera. The results of the model indicated that even in the best case, the detection capabilities of such a system did not provide advantages over the microspectroscopic approach.</p> <p>We presented a novel hyperspectral detection scheme we term Dual-Order Spectral Imaging (DOSI) which is capable of simultaneously measuring spectra of up to 160 individual regions within a microscope's field of view. This technique was applied to measuring shifts of individual nanoparticles and was found to have a peak measurement uncertainty of 1.29 nm, at a measurement rate of 2-5 Hz.</p>

Degree

thesis:*
Department dc:contributor.department
Biomedical Engineering
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nusz, Gregory
Advisor dc:contributor.advisor
  • Chilkoti, Ashutosh

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10161/2264

Chain of custody

source
Harvested from
Duke University
Base URL
dukespace.lib.duke.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Nusz, Gregory. Label-free Biodetection with Individual Plasmonic Nanoparticles. 2010. https://hdl.handle.net/10161/2264