Duquesne
Development of a Rapid Bacterial Quantification Method Based on Droplet Microfluidics
Abstract
dc:description.abstractThe capacity to identify bacteria quickly and accurately is critical for applications such as medical diagnosis, environmental monitoring, and food safety. For instance, sepsis diagnosis requires blood cultures that take as long as 1-5 days, preventing timely intervention and increasing mortality rate. Here, we propose the joint use of microfluidics and a machine learning algorithm for rapid bacterial cell capture and quantification. The combination of high-throughput droplet microfluidics and a support vector machine (SVM) enables analysis and quantification of bacterial samples within as short as 4 hours. We have performed successful encapsulation of pathogenic bacteria such as E. coli, S. enterica, and P. aeruginosa, yielding an average detection accuracy of 98% using our trained SVM model. These results were benchmarked with traditional plating techniques and Petroff-Hausser chamber counts, demonstrating comparable growth curves and validating the promise of digital bacterial enumeration methods.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- One-year Embargo
- Discipline thesis:degree_discipline
- Biomedical Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bliss, Shawn
- Contributors dc:contributor
-
- Melikhan Tanyeri
- John Viator
- Bin Yang
Subjects
dc:subject × 6Rights
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://dsc.duq.edu/etd/2328