Back to search

Durham University

Adaptive Fault Detection and Classification for Microgrids under Grid-Following-to-Grid-Forming Transition

Abstract

dc:description.abstract

The displacement of synchronous generators by inverter-based resources erodes rotational inertia and short-circuit capacity while introducing fast transients that challenge conventional protection philosophies. Microgrids are especially vulnerable: fixed thresholds designed for a narrow operating envelope lead to nuisance trips or missed detections as conditions drift, and existing schemes determine whether a disturbance has occurred but not what type or where it originates. To address these limitations, this thesis develops a three-layer cascaded perception framework that unifies adaptive event detection with lightweight fault classification. Layer 0 monitors four electrical quantities with decision boundaries updated from rolling signal statistics; coordinated coincidence logic triggers the transition from grid-following to grid-forming control only when all indicators simultaneously exceed their adaptive thresholds. Layers 1 and 2 use wavelet features and a k-nearest-neighbour pipeline to classify the fault topology and the affected phase respectively. Per-window classifier outputs are then aggregated into per-event decisions through confidence-weighted majority voting. Validation on a simulated battery and photovoltaic microgrid demonstrates 100% islanding detection with zero false alarms and a mean detection delay of 6.7 ms. The voting mechanism raises the balanced accuracy from 71% at window level to 85% at event level with a 0% severe error rate. An operating-point sensitivity study across 120 fault events confirms that the framework generalises across the tested operating-point range without retraining, maintaining perfect detection and consistent accuracy across four operating conditions. The maximum algorithmic classification latency is 57 ms, well within IEEE 1547 and G99 timing windows. These results show that simple, transparent methods can deliver practical fault diagnostics for microgrids dominated by power-electronic inverters without relying on deep-learning models.

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Durham University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Xinzhuo

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://etheses.durham.ac.uk/id/eprint/16884/

Chain of custody

source
Harvested from
Durham University
Base URL
etheses.dur.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Zhang, Xinzhuo. Adaptive Fault Detection and Classification for Microgrids under Grid-Following-to-Grid-Forming Transition. doctoral thesis, Durham University, 2026. https://etheses.durham.ac.uk/id/eprint/16884/