Back to search

Durham University

Analysis of acrylic polymers by MALDI-TOF mass spectrometry

Abstract

dc:description.abstract

Poly(methyl methacrylate) (PMMA) homopolymers synthesised using 'classical' anionic methods and subsequently studied by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF-MS) are discussed. Specifically, the attempts at different end-group functionalisation reactions, their varying degrees of success, and the characterisation of these functionalized polymers via MALDI are reported. Extra peaks were observed in the spectra of samples containing a tertiary amine end-group. A mechanism for the in situ elimination of H(_2)(g) involving these end-groups, which would fit the observations, is proposed. Two alternative, 'non-classical' routes to the desired materials were investigated, as difficulties in successfully performing capping reactions to give end functionalised PMMA were noted. The first method was a variation of standard anionic polymerisation that involved the use of lithium silanolates, which could be performed at a higher temperature than normal. The second was a controlled free-radical technique known as Reversible Addition-Fragmentation Chain Transfer (RAFT). A lack of control of the polymerisation to the desired degree was observed with the former method. A well-defined RAFT sample was observed to undergo in situ eliminadon also, for which a mechanism involving the dithioester end-group is proposed, and which is supported by MALDI-collision induced dissociation (CID) evidence. The synthesis of block copolymers of various compositions of MMA with r-butyl methacrylate (t-BMA) and hexyl methacrylate (HMA), along with their homopolymers, and their subsequent characterisation is reported. PHMA was analysed easily, in contrast to Pt-BMA. Only copolymers with a high PMMA content were analysed successfully and this has been rationalised in terms of the factors that affect cationisation. The characterisation of equimolar blends of various end-functionalised PMMA samples is reported also. Samples that favour the binding of a metal ion over protonation appear to have a higher ion yield. Once more, these observations are rationalised in terms of the factors that affect cationisation.

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Durham University
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wyatt, Mark Francis

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Identifier Grantnumber
UkUDh:CyT

Chain of custody

source
Harvested from
Durham University
Base URL
etheses.dur.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Wyatt, Mark Francis. Analysis of acrylic polymers by MALDI-TOF mass spectrometry. doctoral thesis, Durham University, 2001. https://etheses.durham.ac.uk/id/eprint/3962/