Back to search

Durham University

The development of an endoprosthesis for the metacarpophalangeal joint

Abstract

dc:description.abstract

Rheumatoid arthritis is a painful and debilitating disease which often afflicts the key joint of the hand, the metacarpophalangeal joint. In the worst cases the diseased joint has to be replaced with an artificial joint or prosthesis. The development of the Durham metacarpophalangeal prosthesis as it was taken from prototypes through to production samples, is described in this thesis. Testing of several Durham prostheses to over 70 million cycles has been carried out on a finger function simulator and consistent wear factors of the order of 0.4 x 10(^-) (^6)mm(^3)/Nm have been measured. These wear factors for the prosthesis were also significantly lower than any found previously. Production samples of the prosthesis have been manufactured together with appropriate surgical instrumentation. Tests of the prosthesis material, cross-linked polyethylene, rubbing against itself, have been undertaken on reciprocating pin on plate rigs and again show total wear factors of the order of 0.4 x lO(^-6)mm(^3)/Nm. Interestingly, it was found that pin wear was very much less than plate wear. The pin on plate tests were extended to include ultra-high molecular weight polyethylene (UHMWPE) rubbing against UHMWPE, as well as both polyethylenes against hard counterfaces and the results are reported. A new finger function simulator has been designed, manufactured and a validation test undertaken. Having written the necessary protocol, in conjunction with clinicians and the prosthesis manufacturer, ethical approval was obtained from the local research ethics committee and the Medical Devices Agency, to permit implantation of the prosthesis in human subjects. Lastly a hand strength measurement device for pre and post operation assessment of patients has been developed and manufactured.

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Durham University
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Joyce, Thomas J

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Identifier Grantnumber
UkUDh:CyT

Chain of custody

source
Harvested from
Durham University
Base URL
etheses.dur.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Joyce, Thomas J. The development of an endoprosthesis for the metacarpophalangeal joint. doctoral thesis, Durham University, 1997. https://etheses.durham.ac.uk/id/eprint/4731/