Back to search

Durham University

Electroanalytical sensors using lipophilic cyclodextrins

Abstract

dc:description.abstract

Lipophilic dialkylated-a-, β- and γ-cyclodextrin derivatives were used as selective ionophores for a series of clinically relevant ammonium ions, and as enantioselective ionophores for both a- and β-aryl ammonium ions. Sensitive and selective potentiometric detection of the local anaesthetics lidocaine and bupivacaine was achieved by using 2,3,6 trioctyl-β-cyclodextrin as the ionophore, leading to micromolar detection limits. Interference studies showed that the simulated clinical electrolyte background caused minimal interference whereas organic interferents of similar size and charge caused some perturbation of the electrode response at a concentration of 10 mmol dm(^-3). An electrode comprising a plasticized biocompatible membrane matrix, TECOFLEX, with 2,6 didodecyl-β-cyclodextrin was incorporated in a flow injection analysis system and the response to lidocaine studied in the presence of human serum. Human serum caused no adverse effects to the electrochemical response of the electrode. These electrodes are, therefore, very suitable for on-line detection of local anaesthetics. Potentiometric detection of tricyclic antidepressants using didodecyl-a-, β- and γ- cyclodextrins as the ionophore, gave micromolar detection limits. Interference from simulated clinical electiolyte background and selected organic interferents gave similar results to those discussed above. In order to lower the detection limit to sub-nanomolar levels modified amperometric electrodes were assembled by depositing a membrane comprising plasticised TECOFLEX, 2,3,6 triethyl-β-cyclodextrin and TKB on the working electrode of a screen printed electrode. Lipophilic 2,6 didodecyl-a- and β-cyclodextrins exhibited enantiomeric discrimination in the binding of propranolol, ephedrine, amphetamine and methamphetamine. These results were confirmed using potentiometric and NMR techniques.

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Durham University
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Palmer, Simon Richard Faunch

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Identifier Grantnumber
UkUDh:CyT

Chain of custody

source
Harvested from
Durham University
Base URL
etheses.dur.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Palmer, Simon Richard Faunch. Electroanalytical sensors using lipophilic cyclodextrins. doctoral thesis, Durham University, 1997. https://etheses.durham.ac.uk/id/eprint/4753/