Back to search

EPFL

Development of Aptamer-Functionalized Graphene Devices for Biosensing of Stress Biomarkers

Abstract

dc:description

Continuous and minimally invasive cortisol monitoring is of strong interest for stress assessment, endocrine studies, and wearable diagnostics. However, the electrical detection of cortisol remains particularly challenging because cortisol is a small, electrically neutral molecule, making its transduction difficult in physiologically relevant ionic environments. This thesis addresses this challenge through the development of a graphene-based biosensing platform for label-free cortisol detection, combining graphene field-effect transistors (GFETs), electrochemical impedance spectroscopy (EIS), and aptamer-based molecular recognition. The first part of this work focused on establishing a reliable graphene sensing platform. Different graphene materials and device architectures were comparatively investigated by Raman spectroscopy and electrical characterization to evaluate graphene quality, fabrication-induced variability, and the effects of passivation and polymer-based processing. This study enabled the rational selection of the most suitable platforms for each sensing modality: Nanolab-fabricated devices with double-sided tape passivation were retained for EIS measurements, while Graphenea GFETs were selected for liquid-gated field-effect sensing. The second part of the thesis was dedicated to the development of a graphene-compatible biofunctionalization strategy enabling selective cortisol recognition while preserving the electrical properties of the transducer. A cortisol-specific aptamer was immobilized through a non-covalent interface based on 1-pyrenebutyric acid \textit{N}-hydroxysuccinimide ester (PBASE). Surface and electrical characterization confirmed successful functionalization and showed that the resulting interface remained compatible with graphene transduction. These investigations also highlighted the central role of Debye screening, which strongly limits direct DC sensing in highly ionic media. The sensing performance of the platform was subsequently evaluated using both DC and AC electrical readout strategies. In diluted buffer, liquid-gated GFETs enabled cortisol detection from sub-nanomolar to micromolar concentrations, validating the sensing concept. In more physiologically relevant conditions, AC-based methods proved to be more effective. EIS enabled cortisol detection in both $1\times$PBS and interstitial-fluid-like solution, with low-nanomolar detection limits and reproducible concentration-dependent responses. A simplified lock-in amplifier readout further confirmed the potential of AC interrogation for portable and integrable electronic readout. Overall, this thesis shows that aptamer-functionalized graphene is a relevant platform for label-free cortisol detection when both the interfacial chemistry and the readout strategy are adapted to the target medium. More broadly, it demonstrates that AC electrical interrogation offers clear advantages over purely DC field-effect sensing for the detection of small molecules in physiologically relevant environments, providing a strong basis for the future development of wearable graphene-based cortisol sensors.

Degree

thesis:*
Grantor dc:publisher
EPFL
Year dc:date
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gilani, Ali
Contributors dc:contributor
  • Ionescu, Mihai Adrian

Subjects

dc:subject × 8

Rights

Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
EPFL
Base URL
infoscience.epfl.ch/server/oai/openaire4
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Gilani, Ali. Development of Aptamer-Functionalized Graphene Devices for Biosensing of Stress Biomarkers. EPFL, 2026. https://doi.org/10.5075/epfl-thesis-11204