Back to search

École de technologie supérieure

Impact of connection details of architectural components on seismic induced repair cost in a shear wall building

Abstract

dc:description

Losses associated with the failure of Non-Structural Components (NSCs) during earthquakes are the most significant contributor to overall building economic loss. Consequently, recent studies have focused on proposing modifications to connection details, element sizes, and materials of NSCs to enhance their seismic performance. In the first step, this study evaluates the effect of using different prediction methods for estimating Engineering Demand Parameters (EDPs) on repair cost of architectural components. Then it quantitatively investigates the repair costs and potential benefits that result from improving the connection details for three commonly used architectural components, namely partition walls, suspended ceilings, and curtain walls subjected to different earthquake intensities. Additionally, it examines the distribution of repair costs associated with the location of the architectural components along the building height. To achieve these goals, a 12-story reinforced concrete shear wall office building located in Montreal on site Class D (stiff soil), was selected as a case study. The study employs the FEMA-P58 building-specific loss estimation methodology to estimate the direct economic loss in terms of repair cost. The results revealed the variation of estimated EDPs (expressed as inter-story drift ratio and peak horizontal floor acceleration) while using different prediction methods and highlight the correlation between calculated EDPs and their corresponding repair costs. Moreover, the results demonstrated that enhancing connection detailing can reduce repair costs of partition walls, suspended ceilings, and curtain walls, by more than 30% at the design level earthquake intensity corresponding to 2% probability of exceedance in 50 years. Furthermore, it is observed that there is a correlation between the earthquake intensity, predicted values of EDPs in each story, and the distribution of repair cost along building height. In the case study building, the estimated loss due to the failure of the selected components is mainly concentrated in the upper third of the building’s height accounting for more than 50% of repair cost.

Degree

thesis:*
Name thesis:degree_name
Mémoire de maîtrise électronique
Level thesis:degree_level
masters
Grantor dc:publisher
École de technologie supérieure
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Daregholi, Seyyed Roozbeh

Subjects

dc:subject × 1

Rights

Language dc:language
en

Identifiers

dc:identifier.*
Identifier
INSERT-YOUR-LIBRARY-ID-HERE3430

Chain of custody

source
Harvested from
ETS (Quebec)
Base URL
espace.etsmtl.ca/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Daregholi, Seyyed Roozbeh. Impact of connection details of architectural components on seismic induced repair cost in a shear wall building. masters thesis, École de technologie supérieure, 2024.