title="Search in OATD">Florida Atlantic University
EXPLORING THE USE OF COMMERCIAL WRIST-WORN WEARABLES FOR ASSESSING CARDIOVASCULAR AND FUNCTIONAL OUTCOMES
Abstract
dc:description.abstractIntroduction: Several new wrist-worn devices estimate VO2 max; however, their validity has not been fully tested. Therefore, the purpose of this study was to determine the validity of three wrist-worn devices (Polar Ignite 3, Garmin VivoActive 5, Garmin VivoSmart 5) for estimating VO2 max. Methods: Twenty-nine participants (21.9±2.1 years) participated.VO2 max was estimated using the three devices’ protocols. COSMED Quark CPET was used to measure VO2 max. Pearson Product-moment Correlations and paired t-tests compared device-estimated values to actual measurements. Agreement between device-estimates and measured values were determined using Bland Altman plots, mean absolute percentage error, and Intraclass Coefficients. Significance was accepted at p< .05. Results: Mean VO2 max was (40.5±8.3 mL/kg/min). VO2 max was significantly lower than means for Polar (10.6±8.4; p< .001), VivoActive (4.7±6.6; p=.003), and VivoSmart (4.5±6.8; p< .001). Conclusion: All three devices overestimated VO2 max compared to measured value. A larger, more diverse sample is needed to confirm these results.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Exercise Science and Health Promotion
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gecaj, Safia Zoi
Subjects
dc:subject × 10Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.fau.edu/etd_general/66