Back to search

title="Search in OATD">Florida Atlantic University

ANION SELECTIVITY STUDIES OF LIQUID-MEMBRANE ION-SELECTIVE ELECTRODES

Abstract

dc:description.abstract

The potentiometric response of liquid-membrane ion-selective electrodes is investigated for a series of inorganic anions. Instantaneous and steady-state measurements are contrasted, and the greater reliability of instantaneous measurements is discussed. The effects of variation of exchanger site, exchanger site concentration, and solvent in the liquidmembrane phase on electrode selectivity are investigated. For electrodes containing substituted and unsubstituted tris(1, 10-phenanthroline) iron(II) complexes and tetraheptylammonium ion as ion-exchange sites, the following sequence of selectivity is established for monovalent anions: PF6- > C104- > SCN-, BF4 , I- > NO3 > Br- > Cl-. The observed selectivity sequence is determined primarily by the charge-to-size ratios and free energies of hydration of the anions.

Degree

thesis:*
Level thesis:degree_level
Thesis

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • REINSFELDER, RONALD EDWARD

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.fau.edu/etd_general_2/93

Chain of custody

source
Harvested from
title="Search in OATD">Florida Atlantic University
Base URL
digitalcommons.fau.edu/do/oai/
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

REINSFELDER, RONALD EDWARD. ANION SELECTIVITY STUDIES OF LIQUID-MEMBRANE ION-SELECTIVE ELECTRODES. Thesis thesis, https://digitalcommons.fau.edu/etd_general_2/93