Non-destructive evaluation of corrosion-damaged pre-stressing steel in jacketed concrete piles

Abstract

dc:description.abstract

A study was performed for the purpose of developing a non-destructive method to evaluate corrosion damaged pre-stressing steel in jacketed concrete piles by using a cover meter. The procedure first involved taking cover meter readings with the pile jacket in place. Subsequently, a portion of the jacket was removed and tendon diameter measurements were taken. A relation for normalized tendon diameter as a function of normalized cover was determined, where normalized cover increased with a decrease in normalized tendon diameter. Finally, it is projected that the cover meter is a useful non-destructive tool to estimate the remaining tendon diameter in the inspection of jacketed, prestressed concrete piles and to this end to characterize the residual structural integrity of piles.

Degree

thesis:*
Level thesis:degree_level
Thesis

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rapa, Martin Tymon

Subjects

dc:subject × 3

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.fau.edu/etd_general_4/1341

Chain of custody

source
Harvested from
title="Search in OATD">Florida Atlantic University
Base URL
digitalcommons.fau.edu/do/oai/
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Rapa, Martin Tymon. Non-destructive evaluation of corrosion-damaged pre-stressing steel in jacketed concrete piles. Thesis thesis, https://digitalcommons.fau.edu/etd_general_4/1341