Development of Smart Phone-based Automated Microfluidic-ELISA For Human Immunodefciency Virus 1

Abstract

dc:description.abstract

The majority of HIV prevalence is found in Sub-Saharan Africa with 36.9 mil- lion living with HIV/AIDS. The cultural implications such as patient non-compliance or denial of available routine medical care can potentially cause limitations on the ef- fectiveness of detecting such virulent pathogens and manage chronic disease. The lack of access to healthcare and further socioeconomic impacts hinder the ability to ade- quately diagnose and treat infection in resource-limited settings. Intervention through diagnosis and treatment helps prevent the spread of transmission, where pre-exposure prophylaxis or active disease prevention measures are not readily available. The cur- rent gold standard for HIV detection is by molecular detection; Reverse-Transcription Polymerase Chain Reaction is widely used that employs cycles of temperature condi- tions that require a thermal cycling platform and typically laboratory space for RNA extraction separate from RT-PCR space required. Serological detection can be ad- vantageous for surveillance and screening, Lateral Flow Assays and Enzyme-Linked Immunosorbent Assay (ELISA) can detect a viral protein (antigen) or antibodies. The ELISA can require at least 12 hours of assay preparation and takes a diagnostic laboratory many resources to run. There is need to develop Point-of-Care (POC) testing that can potentially be used for decentralized testing that can leverage ex- isting technologies such as smart phone capability and routine medical or diagnostic tests with cutting edge applications leveraging micro uidics, nanotechnology and in- tegrated circuit design. Such technologies allow for automated, rapid turnaround and cost-e ective diagnosis of HIV, where these assays could potentially be read- ily deployed. It is such technology that can potentially change the way diagnostics are performed, as POC technology can be rapidly disseminated, enable decentralized testing and, is user-friendly. A novel smart phone-enabled automated magnetic bead- based platform was developed for a micro uidic ELISA for HIV-1 detection at the POC to meet this demand.

Degree

thesis:*
Level thesis:degree_level
Thesis

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Coarsey, Chad Thomas

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.fau.edu/etd_general_6/1680

Chain of custody

source
Harvested from
title="Search in OATD">Florida Atlantic University
Base URL
digitalcommons.fau.edu/do/oai/
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Coarsey, Chad Thomas. Development of Smart Phone-based Automated Microfluidic-ELISA For Human Immunodefciency Virus 1. Thesis thesis, https://digitalcommons.fau.edu/etd_general_6/1680