Analysis of drug substances by using new concepts of HPLC and development of some HPTLC methods

Abstract

dc:description.abstract

Antibiotics and anti-inflammatory drugs are two main categories which are widely used in treatment of different diseases. That is why pharmaceutical analysts are trying to develop different analytical methods for their determination. The Pharmacopoeias are the main source to get the analysis methods of most of the official drugs. Therefore Pharm. Eur. was selected to get the official quantitative and qualitative method of analysis Some representative drugs were chosen for the study in this thesis. Spiramycin, Doxcyclin, Clindamycin and Roxithromycin were examples for antibiotics. For anti-inflammatory drugs, Etodolac and Troxerutin were the selected examples. According to the Pharm. Eur., HPLC and TLC techniques were the official analytical methods for assay, identification and purity test for these drugs. Through the literature of the official and nonofficial HPLC analysis of all these drugs, conventional HPLC column was the only stationary phase which used for their analysis. There are many disadvantages for the use of that type of columns such as long analysis time. To the best of our knowledge there is no reported UPLC-like method for any of these drugs. UPLC is a new type of fast HPLC technique which characterised by the short analysis time. Therefore it was important to transfer these official HPLC methods to UPLC-like method by the use of new analytical columns which packed with more advanced stationary phases such as monolithic and fused core columns. Moreover comparisons were established among all selected stationary phases in terms of chromatographic run time, different flow rates, the produced column back pressure, different types of elution (gradient and isocratic), different mobile system composition, and different sample solvents. Performance parameters as AF, Rs and the theoretical plate number were also studied. The validation parameters (linearity, precession, LOD, LOQ, robustness, reproducibility) were therefore examined for the optimum conditions in each case. The aim of the work was to get the most suitable chromatographic method which can be used instead of the official HPLC method without affecting the resolution of peaks, sensitivity of the method or all validation parameters. Very short analysis time was obtained with all developed methods by using modern columns. For example, the official chromatographic run time for the analysis of CLD was (12 min) and on its transfer to UPLC-like method the analysis time was reduced to (2 min), for SPR the run time reduced from official method (40 min) to developed method (5 min), while for ROX run time was very long with official method (100 min) but by new developed method the run time was only (5 min). Validation parameters were tested for all developed methods as Precision. The within-day repeatability was in the range (0.52- 0.88%) with conventional column and (0.41- 0.87%) with the modern columns. Furthermore, the between-days repeatability was in the ra nge (0.66 –1.25%) with conventional and (0.50 – 0.96%) with modern columns. Modern columns gave more precise integration than that of the conventional columns which can be attributed to the better peak shape and reduced baseline noise. In fact, peak tailing in RP HPLC is particularly prevalent when separating basic compounds. It causes a number of problems including lower Rs, reduced sensitivity and poor precision and quantitation. However symmetric peaks were obtained with the other used stationary phases. The highest AF value was obtained with the use of conventional stationary phase. For example, for Pharm. Eur. Analysis of ETD, CLD or SPR, the obtained AF was 1.4, 1.4 and 1.5 respectively. However, with the developed UPLC-like methods AF was reduced to (1.0 – 1.1) by using fused core and monolithic columns respectively. In the official HPLC methods of some of the selected drugs, the used temperature was not suitable for our lab work. For example, in ROX or DOX official analysis, the temperature were 15 °C and 60°C respectively. However in the developed methods, an ambient temperature was the optimum for the analysis. Moreover, ROX was efficiently separated from its other components in the concentrated sample by the applying the developed method. Acceptable resolution values were obtained with all developed methods. ETD analysis as a representative example, poor separation of ETD from its impurity CON was observed on applying the official method and the obtained Rs was (Rs < 1). On the other hand, on applying the developed gradient elution method, the Rs was raised to (Rs=2.5). Also, a developed UPLC-like method with isocratic elution system for analysis of ETD and its impurity, the Rs values were 1.4, 2.5 and 3.6 by using luna, monolithic and fused core columns respectively. The developed methods were sensitive with low LOD and LOQ. For example, the LOD and LOQ in the analysis of ETD by official method were 0.15 and 0.5 µg/ml respectively, while with the developed method LOD values were reduced to 6, 3.8, 3.3 and 3 ng/ml was by using conventional, luna, monolithic and fused core columns respectively. Also, the LOQ values were reduced to 20, 11.2, 14, and 10 ng/ml by using conventional, luna, monolithic and fused core column respectively. In the analysis of CLD by the official method, the LOD and LOQ values were 61 and 200 ng/ml respectively. However, on transferring to UPLC-like method the LOD values were reduced to 13, 12 and 11 ng/ml by using luna, monolithic and fused core columns respectively. LOQ values were reduced as well to 47, 40 and 38 ng/ml by using luna, monolithic and fused core columns respectively. The low LOD and LOQ values which obtained with the use of monolithic and fused core columns can be attributed to the obtained low background noise. The obtained column backpressure readings were watched. For example, with CLD assay, the flow rate was 1ml/min with column lenght (50 mm), the column backpressure readings were 16, 20, 74, 225 bar by using monolithic, conventional, fused core and luna respectively. Generally higher backpressure resulted with the use of luna because of the small particle size (2.5 µm dp). On using fused core column the backpressure was reduced which attributed to the new technology in particles (2.7 µm) with a high-capacity and very pure porous silica layer which fused to a solid silica core. Monolithic column showed the lowest backpressure reading due to the high permeability of its bimodal structure. For some of the selected drugs “Etodolac, Spiramycin and Troxerutin”, it was found that the official TLC methods were not able to get efficient separation of the drug and its impurities spots. Therefore developments of new TLC methods with the use of horizontal developing chamber were studied. TLC mobile phase and the used sample solvent were optimized. In TRX, The decrease in polarity of the sample solvent showed better results. With the other drugs (SPR and ETD), phosphomolibdic acid reagent was used as new derivatizing reagent with clear background of plate. That gave better detection of the analyte spots rather than using UV lamp detection only which was used in the official TLC method for ETD and anisaldhyde reagent for SPR. In the official TLC purity test of Etodolac there are two different mobile phases with two drying steps were used which time and cost are consuming. One hour analysis time was consumed for the official method procedure. On the other hand, in developed method, the analysis time was reduced to 3 and 1.5 min by using TLC and HPTLC plates respectively, with toluene and acetone in the ratio 1:1 v/v as a mobile system. The developed methods were effective to separate CON and ETD by using TLC and HPTLC plates. The measured TLC Rf values 0.54 and 0.60 for ETD and CON respectively. On the other hand, HPTLC Rf values were 0.54 and 0.67 for ETD and CON respectively. No separation of components of SPR sample was observed by applying official TLC method with 22 min analysis time. However, seven different spots (which related to SI, II, III and other four components in the same sample mixture) were observed by using the developed method and the analysis time was reduced to 3 and 2 min by using TLC and HPTLC plates respectively. According to DAB 1999 procedure, TRX was analysed by TLC methods. Poor shaped spots were observed with Rf values 0.22 and 0.08 for the main spot and blue spot respectively which are less than normal Rf range. That may be due to a poor resolution and separation of the TRX components. By reducing the sample solvent polarity and increasing of the polarity of mobile system, the Rf values and the shape of the separated spots were improved. The obtained Rf values were 0.43 and 0.24 for the main spot and blue spot respectively to be within the expected ranges of DAB, and the developing time was 4 and 2 min by using TLC and HPTLC plates respectively. However, the developed method with using concentrated sample was able to separate the minor compound. The developed TLC method for analysis of SPR was applied to preparative TLC. The developed bands were scratched, extracted and analyzed with HPLC for comparison and confirmation. The obtained results were matched. By using new developed HPLC method with isocratic elution system for ETD analysis with different types of columns and the run time was 2 min. The method was efficient to separate 0.03 µg of CON/ ml of ETD sample in a concentration 0.003 mg/ml. However, the developed TLC and HPTLC methods were also efficient to separate CON from ETD but in 0.05 mg of CON/ml of ETD sample (1mg/ml) within 3 and 1.5 min developing times respectively. By using the UPLC- like method for the analysis of SPR (0.25 mg/ml) at F= 0.8 ml/min, many peaks were observed within 5 min run time. On the other hand, by applying the developed TLC and HPTLC methods, seven different spots were developed with SPR (4 mg/ml) within 3 and 2 min developing times respectively. In all examined official HPLC and TLC methods a significant improvement could be obtained by using UPLC-like methods and optimized conditions of HPTLC methods respectively.

Degree

thesis:*
Department dc:contributor.department
Biologie, Chemie, Pharmazie
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ammar, Amal
Committee members dc:contributor.committeemember
  • Prof. Dr. Surmann
  • Prof. Dr. Morlock

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000014611-9
Dc Identifier Other
FUDISS_thesis_000000014611
FUDISS_derivate_000000006711

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ammar, Amal. Analysis of drug substances by using new concepts of HPLC and development of some HPTLC methods. 2009. https://refubium.fu-berlin.de/handle/fub188/1016