Abstract
dc:description.abstractThe von Willebrand factor (VWF) is the critical determinant of thrombus formation in flowing blood. The multimeric glycoprotein present in human plasma as a series of multimers, containing a variable number of subunits with sizes of 500 to >10,000 kDa, is required for platelet recruitment to injured vessel walls at physiological high arterial shear rates. Binding of VWF to exposed structures of the subendothelium results in platelet tethering, activation and finally adhesion. Furthermore, VWF functions as a carrier for coagulation factor VIII (FVIII) protecting it from rapid proteolytic inactivation. VWF deficiency results in the most common inherited bleeding disorder, the von Willebrand disease (VWD). VWD patients suffer from mild to severe bleeding, and – depending on the severity of haemorrhages – require normalisation of plasma VWF and FVIII levels via VWF/FVIII concentrates. Currently, VWF activity assays are performed under static or low shear rate conditions, albeit in vivo VWF exhibits its function primarily above a critical shear rate of >1,000 per second. The presented work describes the establishment of an in vitro flow-chamber system to investigate VWF-mediated platelet adhesion under defined shear rate conditions present in circulation. The device is extensively characterised with respect to coating, choice of collagen, VWF-collagen binding and exposition of binding domains responsible for platelet interaction, as well as mediation of platelet recruitment under flow, whereas the established model allows the investigation of platelet adhesion solely depending on the presence of VWF. Results suggest the contribution of all VWF multimers to platelet adhesion on collagen due to binding of low- as well as high molecular weight VWF multimers at all shear rates investigated. Platelet binding domains co-localised to the VWF molecule were exposed to a similar extent. Implementation of the flow-chamber model to compare five commercially available VWF-containing concentrates showed effective platelet recruitment for all concen¬trates tested, but revealed significant differences in the degree of platelet adhesion, which did not correlate with the VWF multimer distribution of the applied sample. Fractionation of VWF into different sized multimers and investigation of collagen-binding kinetics using surface plasmon resonance as well as their ability to mediate platelet adhesion under flow revealed a dimished capability for multimers below four, but a comparable activity of intermediate- and high molecular weight multimers. In conclusion, the established flow-chamber system provides a promising tool for the investigation of VWF function under defined shear rate conditions. Subsequent studies investigating the impact of VWF triplet structure as well as the implementation of the system to study VWD variants will show the contribution of the developed flow device to a possible use in classification of VWD and quality control of VWF-containing concentrates.
Degree
thesis:*- Department dc:contributor.department
- Biologie, Chemie, Pharmazie
- Year dc:date.issued
- 2009
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fuchs, Birte
- Committee members dc:contributor.committeemember
-
- Prof. Dr. C. Niemitz
- Prod. Dr. R. Horstkorte
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000009897-6
- Identifier URI
- http://dx.doi.org/10.17169/refubium-14603
- Dc Identifier Other
-
FUDISS_thesis_000000009897
FUDISS_derivate_000000005572