Freie Universität Berlin
Fate of para-toluenesulfonamide (p-TSA) during drinking water treatment and in-situ enhanced remediation
Abstract
dc:description.abstractThe industrial micropollutant para-toluenesulfonamide (p-TSA) has several applications. It is applied as plasticizer, as intermediate for pesticides and as fungicide in paints and coatings. p-TSA is also the primary degradation product of the common disinfectant Chloramine-T. Therefore, p-TSA has several potential sources in wastewater and can represent a serious problem in partly closed water cycles where groundwater is used for drinking water production. p-TSA was found to be ubiquitous in the Berlin wastewater, sewage water and groundwater. The highest concentrations (up to 30 g L-1) were encountered in the groundwater of the catchment area of a drinking water treatment plant (DWTP). The toxicity of p-TSA can be considered as moderate since it is toxic to algae but not to fishes and daphinids; however, dedicated tests are advised if in the future larger amounts of p-TSA are used in consumer products. Following the guidelines of the German Federal Environmental Protection Agency (UBA), the concentration limit for p-TSA in drinking water is 0.3 g L-1. Such a concentration is around 100 times lower than the maximum concentrations encountered in Berlin’s groundwater. Motivated by the occurrence of high p-TSA concentrations in the groundwater used for drinking water production, a series of intensive investigations of the distribution and behaviour of p-TSA in different aquatic compartments started a few years ago. The present study is a continuation of these investigations and aims at providing further knowledge on several aspects of the contamination by p-TSA that are still not well understood. Chapter 1 is a general introduction to the problem of groundwater contamination by sewage farms. Chapter 2 documents a numerical modelling study using the finite element method to determine p-TSA degradation rate constants during rapid sand filtration. Data used for simulations were obtained by a previous column experiment carried out in the filter hall of the DWTP of Friedrichshagen. During the experiment, aerated abstracted groundwater was infiltrated through the column applying different infiltrations rates (from 2 to 6 m h -1). Experimental breakthrough curves and depth profiles were modeled with the software Comsol Multiphysics 3.3. p-TSA degradation was simulated with first-order kinetics and Michaelis Menten kinetics. Simulation results showed that p-TSA was readily removed during drinking water treatments. Degradation rate constants were temporally variant probably due to the adaption of microbes to the changes of infiltration rates. Higher degradation rate constants were observed close to the column inlet where probably a higher microbial activity could develop. Degradation rate were generally very high probably because the filter material had been in contact with the raw groundwater for decades and an adapted microbiology had developed. Chapter 3 reports a laboratory column experiment using aquifer material and groundwater from the field site that was performed to investigate the potential removal of p-TSA by applying injection of oxygen. Initially, the column was operated under completely anoxic conditions. Successively, oxic conditions were simulated by adding compressed air to the experimental system. Results revealed that p-TSA was not removed under anoxic conditions, whereas it was fully removed under oxic conditions. The experimental results were modeled through a one dimensional reactive transport model that was set up using the Comsol Multiphysics 3.3 software. p-TSA degradation was simulated with first- order kinetics and the obtained degradation rate constants were 3 to 4 orders of magnitude lower than those obtained during rapid sand filtration. Experimental results clearly displayed that air or O2 injections in the aquifer can be a successful strategy for p-TSA remediation. Chapter 4 describes a field study investigating the distribution and persistence of p-TSA under natural aquifer conditions. p-TSA is considered not to be geochemically retarded and under anoxic conditions it should behave conservatively. To refine the current knowledge of p-TSA transport and degradation at the field scale, measurements of p-TSA and major ions were performed from the Berlin Water Company (BWB) at nine locations between 2005 and 2010. The measurements showed that p-TSA is retarded in the same manner as chloride (Cl-) indicating hydraulic retardation due to low permeability layers where groundwater is immobile. To verify the non-reactive transport of p-TSA under field conditions, a vertical 2D transport model was set up with PMWIN 8, using the modules Modflow and MT3DMS. The immobile domains were considered applying the dual-domain mass transfer approach. The measured data for p-TSA and Cl- concentrations were successfully reproduced, supporting the hypothesis that both compounds behave conservatively but that at the field site they are hydraulically retarded. Prognostic simulations with the calibrated 2D transport model revealed that without any remediation measures the groundwater quality near the drinking well galleries will be affected by high p-TSA loads for more than a hundred years. In chapter 5, the interpretation of available data concerning the effects of air/oxygen injections on p-TSA removal at the field site is provided. Injections of air and oxygen into the aquifer were performed by the Fugro Consult GmbH on behalf of the BWB. The injections aimed to develop a migration barrier for the ammonium contamination plume to remediate groundwater before arriving at the abstraction well galleries. As demonstrated in the previous chapters, the injections could be a suitable strategy also for the removal of p-TSA. The injections were performed by six injection tubes installed in a line perpendicular to the main groundwater flow direction. To sufficiently supply the aquifer with oxygen, injections were carried out at different depths. The groundwater quality was monitored using a series of monitoring wells located between and downgradient of the injection tubes. Data obtained during three years of active application of the remediation measure were analysed by giving particular attention to the effects of the injections on p-TSA and ammonium concentrations. p-TSA and ammonium appeared to behave similarly, indicating removal only in few monitoring wells. However, both substances were not degraded at the majority of the monitoring wells even under oxic conditions. This phenomenon may be related to antiseptic conditions as a result of elevated oxygen concentrations. A list of further potential reasons for the unsuccessful application of the remediation measure was given and some improvements of the system were suggested. For the interpretation of the p-TSA and ammonium field data, a one-dimensional reactive transport model was set up using the computer code PHREEQC-2. The model considers p-TSA degradation, nitrification, denitrification, pyrite oxidation and organic matter degradation. The resulting disagreements between measured and simulated data are mainly attributed to (i) three-dimensional effects controlling the oxygen distribution, (ii) transient flow conditions and (iii) reduced microbial activity associated with high oxygen concentrations not considered in the model.
Degree
thesis:*- Department dc:contributor.department
- Geowissenschaften
- Year dc:date.issued
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Meffe, Raffaella
- Committee members dc:contributor.committeemember
-
- PD. Dr. Claus Kohfahl
- Prof. Dr. Gudrun Massmann
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000025083-9
- Identifier URI
- http://dx.doi.org/10.17169/refubium-5332
- Dc Identifier Other
-
FUDISS_thesis_000000025083
FUDISS_derivate_000000010103