Freie Universität Berlin
A novel method of early detection of congestion in heart failure using bioimpedance on a pig model
Abstract
dc:description.abstractCongestive heart failure (CHF) is associated with an enormous human and economic burden. This is due to resulting high mortality, progressive and prolonged morbidity and recurrent hospitalization. A large portion of the costs arises from mandatory hospitalization and re-hospitalization for decongestion. Adjusting medication in early stages of deterioration could improve long term outcome, reduce re-hospitalization rates and costs. The current diagnostic and monitoring procedures for heart failure patients have two major setbacks: First, they are incapable of predicting preclinical decompensation. This leads to the disease being diagnosed so late that hospitalization becomes mandatory. Secondly, they are not routinely usable in the home setting by heart failure patients. A system which is free of these setbacks is currently not readily available. Bioimpedance in conjunction with telemedicine offers a possible solution. Bioimpedance (Z) is the resistance of biological tissue to electric current. The lung has unique electrical properties: The air inside acts as an insulator, the alveoli as capacitors and blood as a good conductor. The circulatory close proximity of the lung and the heart makes the lung sensitive to fluid overload. These unique properties make bioimpedance monitoring of the lung viable. Accumulation of fluid during pulmonary edema results in a measurable reduction of the Z. This was used as the basis of this study. Telemonitoring allows monitoring of physiological variables measured in patients at home by physicians and caretakers by making use of standard telecommunication technology e.g. telephone, cable etc. This would allow the close monitoring of heart failure patients and facilitate early intervention in case of worsening and so prevent hospitalization. Consequently, rates of admission to hospital would be reduced and discharge accelerated. The epidemiological and financial significance of heart failure predicts home care as a cost-effective solution with a good potential. The viability of both telemedicine in monitoring patients at home and bioimpedance in monitoring heart failure has been examined separately in numerous publications. Aim of this study was to determine if local thoracic bioelectrical impedance (Z) correlates with respiration parameters (tidal volumes and respiration rates), fluid overload (fl) and cardiac output (CO) and could therefore serve as a basis for a heart failure monitoring system. In seven juvenile farm pigs (average weight 32.5±5 kg), a subcutaneous passive can with four electrodes was implanted on the left side of the chest. After obtaining baseline values, acute heart failure and fluid overload were induced in two steps (reduction of CO to 70-80% and then to 50-60% of baseline value) by gradual injection of 4.3±2.0 mg Metoprolol and Verapamil for each step together with fluid administration (259±72ml 0.9% saline and 6% hydroxyethyl starch each for each step). Stepwise injection of Metoprolol, Verapamil and fluid resulted in a reduction of cardiac output, LVEF and MAP and an increase in MPAP, PCWP and CVP. The percentage change in Z decreased from baseline to the first and second step of fluid load. A linear trend was found for this decrease (R2=0.83) Several studies have confirmed the viability of using pulmonary electrical impedance to measure changes in lung fluid both in humans and animals with results in conformation with those of this study. The results of this research work show a possibility of measuring lung fluid content by thoracic bioelectrical impedance as a possible parameter of non-physiological changes in lung fluid. A good application could be in heart failure where lung congestion occurs. Although the results of this particular porcine study may be applicable to humans to a limited extend, there are currently studies confirming its applicability to humans. If applied, this method of hemodynamic monitoring could lead to an improvement of quality of life, less mortality and less hospitalization and associated costs.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2010
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mutwol, Lawrence
- Committee members dc:contributor.committeemember
-
- Priv.-Doz. Dr. P. Fotuhi
- Prof. Dr. med. S. Felix, Prof. Dr. med. H. U. Klein
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000019510-6
- Identifier URI
- http://dx.doi.org/10.17169/refubium-15639
- Dc Identifier Other
-
FUDISS_thesis_000000019510
FUDISS_derivate_000000008426