Back to search

Freie Universität Berlin

Activity monitoring in dairy cattle: Evaluation of a technical estrus detection device

Abstract

dc:description.abstract

In my first study farmers were surveyed, who use an automated activity monitoring (AAM) system for the detection of estrus. The objective of this study was to gain an overview of current management practices for of estrus detection and to learn more about the practical aspects. The farmers were surveyed about the influences on animal environment, business processes, methods of estrus detection before and after installing the AAM, handling and overall impression of efficiency. Overall, 94.1% of surveyed managers were satisfied with the AAM and almost all of them (94.5%) would install the system again. The results show that the AAM represents a well accepted system with the potential to reduce the time required for estrus detection and the administration of hormones. In the second trial the objective was to validate the AAM and compare its efficiency to estrus detection by visual observation (VO). More specifically the efficiency and accuracy of AAM Systems were identified and the reproductive performance of cows by AAM or VO or one of the two methods (EOM) compared. In total 1,004 potential cycles were analyzed from 348 cows. Estrus detection rate (EDR) were calculated for 21 d after the voluntary waiting period (VWP + 21), 42 d (VWP + 42), and 63 d (VWP + 63). In the time period VWP + 21 (P> 0.05) the EDR differed barely between AAM (42.1%) and VO (37.3%) – but the EDR of EOM differed (56.3%, p <0.05) significantly. The estrus detection by AAM achieved an efficiency (number of correctly recognized estrues / total number of cycles * 100) of 35.6% and an accuracy (number of the estruses / (number of true + false the estruses correctly identified) * 100) of 83.8%, Visual observation (VO) led to an efficiency of 34.3% and an accuracy of 75.1%. The pregnancy rate was 200 DIM with AAM (66.8%) and EOM (68.8%) and with VO (57.1%, p <0.05). From AAM system recognized cows (P <0.05) showed a 1.37 times higher Risk to conceive than cows that were detected by VO (P <0.05). The results show that an automated activity monitoring system can support estrus detection in dairy cows. However, the exclusive use of such a system can not be recommended.

Degree

thesis:*
Department dc:contributor.department
Veterinärmedizin
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Michaelis, Ina
Committee members dc:contributor.committeemember
  • Prof. Dr. Heuwieser
  • Prof. Dr. Holger Martens
  • Prof. Dr. Rudolph Staufenbiel

Subjects

dc:subject × 7

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000102769-7
Dc Identifier Other
FUDISS_thesis_000000102769
FUDISS_derivate_000000019948

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Michaelis, Ina. Activity monitoring in dairy cattle: Evaluation of a technical estrus detection device. 2016. https://refubium.fu-berlin.de/handle/fub188/1166