Back to search

Freie Universität Berlin

A High-Field / High-Frequency Electron Paramagnetic Resonance Spectrometer (360 GHz / 14 T)

Abstract

dc:description.abstract

# Abstract Electron paramagnetic resonance (EPR) has traditionally been carried out at microwave frequencies between 9 and 10 GHz (X-band) and magnetic fields around 0.3 T. In the last twenty years, however, a strong trend has evolved to expand the range of microwave frequency and magnetic field to higher values. The origin of this development lies in the fact that high field / high frequency EPR offers several great advantages when compared to conventional X-band EPR. The most important of these advantages are the increased spectral resolution, a gain in sensitivity for samples of limited size or quantity, the accessibility of zero-field fine structure transitions that are ´EPR-silent´ at lower frequencies and the sensitivity to different motional frequency regimes. In the course of the work presented here, a spectrometer operating at a frequency of 360 GHz and at magnetic fields up to 14 T was built up. In conjunction with the existing X-band (9.5 GHz) and W-band (95 GHz) spectrometers this considerably expands the scope of measurement frequencies accessible in our workgroup. As has become obvious already from the experiences gained from the extension to W-band spectroscopy, performing EPR experiments at multiple frequencies provides a better insight into physical and chemical processes than can be achieved by observations at a single frequency only. Considering the limited number of working spectrometers, it is easily understandable that so far no single best way of dealing with the technical problems encountered when working with frequencies above 200 GHz has evolved. With the strong focus of our workgroup on the elucidation of the structure and functioning principles of bioorganic systems it was of particular interest to see whether the chosen spectrometer configuration would provide a sufficiently high sensitivity and resolution to observe well resolved spectra of paramagnetic biomolecules. One of the goals of this work therefore was to characterize the performance of the spectrometer and to get a better idea about which parts should be optimized. This thesis is structured as follows: Chapter 3 will give a motivation for the extension of EPR to higher microwave frequencies and magnetic fields. In chapter 4, an overview of the theory of Gaussian optics will be given to the extent needed to describe the resonator and transmission line of the spectrometer. The experimental setup of the spectrometer will then be described, followed by the description of the numerical simulation routines developed for the interpretation of the observed spectra. Subsequently, the first experimental results obtained with the spectrometer will be presented. In a final discussion, the main results will be summed up and the most imminent future projects will be plotted out.

Degree

thesis:*
Department dc:contributor.department
Physik
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fuchs, Martin R.
Committee members dc:contributor.committeemember
  • Prof. Dr. Klaus Möbius
  • Prof. Dr. Nikolaus Schwentner

Subjects

dc:subject × 1

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-2000000073
Dc Identifier Other
FUDISS_thesis_000000000346
FUDISS_derivate_000000000346

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Fuchs, Martin R.. A High-Field / High-Frequency Electron Paramagnetic Resonance Spectrometer (360 GHz / 14 T). 2000. https://refubium.fu-berlin.de/handle/fub188/12622